1.1.

ELECTRICAL SAFETY.

WARNING! It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and

all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety

devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD

(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD with portable products that are plugged

into an electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by

contacting your Sealey dealer. You must also read and understand the following instructions concerning electrical safety.

1.1.1. The

Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2. The

Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance

and the safety of the appliance operator. If in any doubt about electrical safety, contact a qualified electrician.

1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power

supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4. Ensure that cables are always protected against short circuit and overload.

1.1.5. Regularly inspect power supply, leads, plugs for wear and damage and all electrical

connections to ensure that none are loose.

1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power

supply to be used and check that plugs are fitted with the correct capacity fuse. A 13Amp plug

may require a fuse smaller than 13Amps for certain products, see fuse rating at right.

1.1.7.

DO NOT pull or carry the powered appliance by its power supply lead.

1.1.8.

DO NOT pull power plugs from sockets by the power cable.

1.1.9.

DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have

repaired by a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted.

In case of damage, cut off and fit a new plug according to the following instructions (discard

old plug safely).

(UK only - see diagram at right). Ensure the unit is correctly earthed via a three-piN plug.

a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

b) Connect the BROWN live wire to live terminal ‘L’.

c) Connect the BLUE neutral wire to the neutral terminal ‘N’.

b) After wiring, check that there are no bare wires, that all wires have been correctly connected, that cable outer insulation

extends beyond the cable restraint and that the restraint is tight.

Double insulated products are fitted with live (BROWN) and neutral (BLUE) wires only. Double insulated products are always marked

With

this symbol . To re-wire, connect the brown & blue wires as indicated above. DO NOT connect the brown or blue to the

earth terminal.

1.1.10. Some products require more than a 13Amp electrical supply. In such a case, NO plug will be fitted. You must contact a qualified

electrician to ensure a 30Amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug and

socket with your electrician.

1.1.11.

Cable extension reels. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD

fitted is recommended since any product which is plugged into the cable reel will be protected. The section of the cores of the cable

is important. We suggest 1.5mm² section as a minimum but to be absolutely sure that the capacity of the cable reel is

suitable for this product and for others that may be used in the other output sockets, we recommend the use of 2.5mm² section cable.

INSTRUCTIONS FOR:

PROFESSIONAL BANDSAWS 200 & 245mm

MODEL No's:

SM1303, SM1304

1. SAFETY

1.2.

GENERAL SAFETY

WARNING! Disconnect the saw from the mains power before changing saw blades and accessories, servicing or performing maintenance.

Mount the saw to a secure surface such as a workbench.

Keep area clean and tidy and free from unrelated materials and ensure there is adequate lighting.

Maintain the

saw in good condition (use authorised service agent only).

Replace or repair damaged parts. Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

Keep the machine clean and the blade sharp for best and safest performance. Check moving parts alignment regularly.

Before each use check saw blade condition. If worn or damaged replace immediately.

Place the blade guide to within 3mm of the material being cut.

WARNING! Keep all safety guards and holding screws in place, tight and in good working order. Check regularly for damaged parts.

A guard or any other part that is damaged should be repaired or replaced before the saw is next used. The safety guard is a mandatory

fitting.

Remove adjusting keys and wrenches from the saw before turning it on.

Wear approved safety eye protection, ear defenders, safety gloves and, if dust is generated, respiratory protection.

Remove ill fitting clothing. Remove ties, watches, rings, and other loose jewellery, and contain long hair.

Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.

Keep children and unauthorised persons away from the working area.

Secure unstable work piece with a clamp, vice or other adequate holding device.

Avoid unintentional starting.

Keep hands and fingers at a safe distance from the saw blade, especially at the end of a cut. Guide the work with a piece of

wood or push rod rather than your fingers when cutting small pieces.

RECOMMENDED

FUSE RATING - 5AMP

Original Language Version

SM1303, SM1304 Issue: 6(S) - 03/11/14

IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE

PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR

PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions

and properly maintained, give you years of trouble free performance.

© Jack Sealey Limited

This manual is related to the following products: