2. introDuction & sPecification

3.1. Air Supply

3.1.1. Ensure the sander air valve (or throttle) is in the "Off" position before connecting to the air supply.

3.1.2. You will require an air pressure between 70-90psi, and an air flow according to the specification above.

3.1.3. p

WarninG! Ensure the air supply is clean and does not exceed 90psi while operating the sander.

Too high an air pressure and/or unclean air will shorten the product life due to excessive wear, and may

be dangerous, causing damage and/or personal injury.

3.1.4. Drain the air tank daily. Water in the air line will damage the sander and will invalidate your warranty.

3.1.5. Clean air inlet filter weekly. Recommended hook-up procedure is shown in fig.1.

3.1.6. Line pressure should be increased to compensate for unusually long air hoses (over 8 metres).

The minimum hose diameter should be 1/4” I.D. and fittings must have the same inside dimensions.

3.1.7. Keep hose away from heat, oil and sharp edges. Check hoses for wear and make certain that all

connections are secure.

3.2. Couplings

Vibration may cause failure if a quick change coupling is connected directly to the air sander. To

overcome this, connect a leader hose to the sander. A quick change coupling may then be used to

connect the leader hose to the air line recoil hose.

See figs.1 & 2.

3. PreParinG sanDer for use

1.2.

LeaD Paint WarninG!

Paint once contained lead as a traditional ingredient. The dust caused by the removal of such paint is

toxic and must therefore be avoided. The following action must be taken before using the sander on

a surface that you suspect may contain lead paint.

1.

User must determine potential hazard relating to age of paint to be removed (modern paints do

not have lead content).

2.

DanGer! Keep all persons and pets away from the working area. The following are particularly

vulnerable to the effects of lead paint dust: Pregnant women, babies and children.

3.

We recommend personal protection by using the following safety items:

a) Paint Spray Respirator (Our ref SSP16EN)

b) PE Coated Hooded Coverall (Our ref SSP267). c) Latex Gloves (Our ref SSP24).

4.

Take adequate measures to contain the paint dust, flakes and scrapings.

5.

Continue to wear safety equipment as in (3) and thoroughly clean all areas when task is complete.

6.

Ensure paint waste is disposed of in sealed bags or containers.

Model No:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . GSA70

Disk Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50mm

Thread Size: . . . . . . . . . . . . . . . . . . . . . . . . . . M6x1mm

Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . .0.3hp

Free Speed: . . . . . . . . . . . . . . . . . . . . . . . . . 15000rpm

Orbit Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ø3mm

Air Consumption: . . . . . . . . . . . . . . . . . . . . . . . . 4cfm

Operating Pressure: . . . . . . . . . . . . . . . . . . . . . . . 90psi

Air Inlet Size: . . . . . . . . . . . . . . . . . . . . . . . . . .1/4”BSP

Weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.66kg

Noise Power: . . . . . . . . . . . . . . . . . . . . . . . . . . 94dB.A

Noise Pressure: . . . . . . . . . . . . . . . . . . . . . . . . 83dB.A

Measured Vibration Emission Value: . . . . . . . . 4.6m/s²

Uncertainty Value (k):. . . . . . . . . . . . . . . . . . . 1.84m/s²

Original Language Version

Composite cover moulded around lightweight aluminium alloy housing reduces effects of chill on operator’s hands

and provides added control. Air motor with quality bearings for smooth and powerful operation. Fitted with safety

release trigger control to prevent accidental operation. Exhaust outlet adjusts 360° keeping air flow away from