5.3. OPERATING

5.3.1. Connect the grinder to the air supply.

WARNING! Ensure you have read, understood and apply safety instructions.

5.3.2. To start, hold firmly and push the trigger locking lever forward whilst depressing trigger.

5.3.3. The bit must be running at its maximum speed before attempting to grind the workpiece.

5.3.4. Slowly and smoothly bring the grinding bit toward the workpiece (avoid jerky movements).

Exert adequate pressure on the grinder to grind according to the type and size of the material you are working with.

Avoid subjecting bit to excessive strain or harsh impacts.

Always hold grinder firmly and ease grinding bit against workpiece.

Maintain a controlled, adequate progression.

DO NOT allow grinder to free run for an extended period as this will shorten its life.

5. OPERATION

5.1

Fitting Grinding Bits

WARNING! Disconnect from the air supply before changing grinding bit.

5.1.1. Check that grinding bits are not damaged in any way such as cracks, deformations or splinters etc. Damaged bits must not be used.

5.1.2. Use spanners provided to loosen collet locking collar. Insert appropriate collet and grinding bit and re-lock collar.

5.2

Fitting Sanding Discs

5.2.1. Make sure that the 6mm collet is inserted.

5.2.2. Insert the sanding disc adaptor into the collet and tighten with spanners.

5.2.3. Take the appropriate sanding pad and screw it clockwise onto the adaptor.

5.2.4. Screw on a corresponding sanding disc onto the sanding pad, turning it clockwise to secure.

WARNING! Disconnect grinder from air supply before changing accessories, servicing or

performing maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will

invalidate the warranty.

6.1. If the air supply system does not include an oiler lubricate the air grinder daily with a few drops of Sealey air grinder oil dripped into the air

inlet to prolong its life.

6.2. Clean the grinder after use.

6.3. Loss of power or erratic action may be due to the following:

a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose connectors. To remedy check the air

supply and follow instructions in chapter 3.

b) Grit or gum deposits in the grinder may also reduce performance. If your model has an air strainer (located in the area of the air inlet),

remove the strainer and clean it. Flush the grinder out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin. Allow to dry

before use.

6.4. For a full service contact your local Sealey service agent.

6.5. When not in use, disconnect from air supply, clean grinder and store in a safe, dry, childproof location.

6. MAINTENANCE

Environmental Protection

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycling centre

and disposed of in a manner which is compatible with the environment. When the product becomes completely unserviceable and requires disposal,

drain off any fluids (if applicable) into approved containers and dispose of the product and the fluids according to local regulations.

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk,

email [email protected] or telephone 01284 757500.

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

01284 757500
01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

GSA674K Issue: 1 - 05/12/14

Original Language Version

© Jack Sealey Limited

GSA674K Issue: 1 - 05/12/14

Original Language Version

© Jack Sealey Limited