WARNING! Disconnect the grinder from air supply before changing the disc, servicing or performing

maintenance. Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be

dangerous and will invalidate the warranty.

5.1. Lubricate the grinder daily with a few drops of good grade air tool oil, such as Sealey ATO/500 or

ATO1000S, dripped into the air inlet before use or dispensed automatically through an air system oiler,

such as Sealey model SA2001L.

5.2. Clean the grinder after use and change the disc when worn or damaged.

5.3. Loss of power or erratic action may be due to the following:

a) Excessive drain on the air supply. Moisture or restriction in the air line. Incorrect size or type of hose

connectors. To remedy check the air supply and follow instructions in Section 3.

b) Grit or gum deposits in the grinder may also reduce performance. Flush the grinder with gum solvent

oil or an equal mixture of SAE No.10 oil and kerosene. Allow to dry before use.

If you continue to experience problems, contact your local Sealey service agent.

5.4. When not in use, disconnect from air supply, clean grinder and store in a safe, dry, childproof location.

4.

OPERATING INSTRUCTIONS

5. MAINTENANCE

WARNING! Ensure that you read, understand and apply the

safety instructions before use.

4.1. Assembly: - The SA151.V2 comes with a handle, a spanner and a hex key.

4.1.1. The handle screws into the left or right-hand side of the head.

4.1.2. Remove the disc locking hex bolt from the grinder spindle. Use the spanner supplied to hold the lower

flange and loosen/tighten the hex bolt.

4.1.3. Fit the grinding disc (not supplied) to the spindle in between the two flanges and secure with the hex

bolt. Use only discs with speed ratings equal to, or higher than the speed rating of the grinder.

4.1.4. Connect air supply to grinder. Push safety button (adjacent to trigger) with thumb and squeeze the

control valve lever to check that the grinder is working correctly.

4.2. Operating: - DO NOT apply excessive pressure, let the grinder do the work for you. Start the grinder

and bring the disc to the the work surface evenly and slowly. Move the grinder back and forth in

overlapping areas. Remove the grinding disc from the work surface before stopping the grinder.

Regularly check the condition of the disc and always change if worn, cracked or otherwise damaged.

DO NOT free-run the grinder off the workpiece for extended periods as this will shorten the life of the

bearings.

fig.1

3.2. Couplings. Vibration may cause failure if a quick change coupling is connected directly to the grinder. To

prevent this, connect a leader hose - Sealey model number AH2R or AH2R/38 - to the grinder. A quick

change coupling may then be used to connect the leader hose to the air line recoil hose. See figs.1 & 2.

fig.2

SA151.V2 Issue: 2(SP)- 31/07/13

Original Language Version

© Jack Sealey Limited

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: No liability is accepted for incorrect use of this product.

WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.

INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group,

Kempson Way, Suffolk Business Park

,

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email