Unpacking the DFE-Platinum Module

3-2 Installation

Unpacking the DFE-Platinum Module

Unpack the DFE‐Platinum module as follows:

1.

Open the box and remove the packing material protecting the DFE‐Platinum module.

2.

Verify the contents of the carton as listed in 

Table 3‐1

.

3.

Remove the tape seal on the non‐conductive bag to remove the DFE module.

4.

Perform a visual inspection of the DFE‐Platinum module for any signs of physical damage. 
Contact Enterasys Networks if there are any signs of damage. Refer to “

Getting Help

”  on 

page xiii for details.

Installing Optional Network Expansion Modules

A Phillips screwdriver is needed to install an optional NEM into the 2G4082‐25.

At the time of this printing, only the 7G‐6MGBIC‐A NEM is available for the 2G4082‐25. Refer to 
your release notes for the latest available Ethernet interface modules. The 7G‐6MGBIC‐A provides 
six Gigabit port slots for optional Mini‐GBIC connections.

Installing an optional NEM involves 

removing the coverplate from the DFE‐Platinum module,

attaching the NEM to the DFE‐Platinum module, and

if required, installing Mini‐GBICs.

For more information, refer to the Quick Reference that was shipped with your NEM, or the Matrix 
Network Expansion Module Hardware Installation Guide
 located on the Enterasys Networks website. 

Installing Module into Matrix E7 or N7 Chassis

To install a 2G4082‐25 into a Matrix E7 or Matrix N7

chassis, proceed directly to “

Preparation

” on 

page 3‐3 to start the installation process.

Table 3-1 Contents of DFE-Platinum Module Carton

Item

Quantity

DFE-Platinum Module (2G4082-25

)

1

This Installation Guide

1

Customer Release Notes

1

Note: Install any optional equipment before installing the 2G4082-25 into a chassis

.

Caution: Failure to observe static safety precautions could cause damage to the DFE module.
Follow static safety handling rules and wear the antistatic wrist strap.

Do not cut the non-conductive bag to remove the module. Sharp objects contacting the board or
components can cause damage.

Precaución: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad para la
manipulación del producto y no olvide utilizar la pulsera antiestática.

No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto cortante
entra en contacto con la placa o con los componentes, éstos podrían dañarse.

This manual is related to the following products: