[3] Alarm function - Saving image files to the remote host by
input of the alarm signal
By shorting the alarm signal input terminal <1> or <2> on the back panel of the
Camera
to
the GND terminal, the
Camera
can be moved to the preset position assigned to each
terminal. (Refer to [1] “Alarm input” in paragraph 7 “ Alarm in/out terminals” on page 22.)
At this time, it is possible to save image files to the host on the network specified for File
Transfer on the Alarm Configuration page. When this function is utilized, the FTP server
must be in operation in the host at the saving destination.
Note:
If alarm signals are input continuously at short intervals, the image
corresponding to the preset position cannot be saved in some cases.
Also, all the images as many numbers as alarm inputs could not be saved in
some cases.
Note:
Image could not be saved on some network conditions.
The
Camera
provides the following two procedures for alarm setting.
• Connecting to the
Camera
from the host on the network through the Web browser.
• Connecting to the
Camera
from the host on the network through telnet.
Here, the setup procedure using the Web browser is described.
For the setup procedure using telnet, consult your dealer or an authorized ELMO service
center.
Setting
• Enter the IP address or host name (if allocated) of the
Camera
, following [http://],
followed by [/config.htm], in the Address bar’s text box of the Web browser. For
example, enter the IP address of this
Camera
as “http://192.168.0.100/config.htm”,
since it has been factory set to 192.168.0.100.
• When the Authentication page is displayed, undergo authentication by the [root]
account. Authentication cannot be cleared successfully by any other account. (The
Authentication page is not displayed, since no password has been set in as-shipped
condition.)
• When the Configurations page is
displayed in the Web browser, click the
link
[Alarm Configuration]
.
• When the Alarm Configuration page is
displayed, specify whether to enable or
disable the alarm action. To disable the
alarm action, select the radio button
[No action]
. To enable it, select the
radio button
[File transfer]
. To reset
the changed settings to the original
settings, click the clear button
[CLEAR]
.