Appendix D:

Programming the LCM

The LCD panel module (LCM) is designed to provide

real-time operating status and configuration information

for the system. For sample LCM code, see LCM foler in

the Driver and Manual CD. The driver and the program

library can also be found in the folder.
The system supports the following 2 kinds of LCM:

Parallel Text-based LCM: The LCM connects to the

motherboard’s parallel port. The LCD screen can

display 2 lines, 16 (or 20) characters per line.
USB and Serial Text or Graphic-based LCM: Our next

generation LCM. Lanner engineers design a common

source code to be deployed on these two differently

interfaced LCM modules. Jumpers are used to select

between text and graphic types. See next section.

For Parallel Text-based LCM

Build
To build program source code on Linux platform, please

use the following steps as a guideline:
1. Extract the source file:
# tar -xzvf plcm_drv_v0XX.tgz
(0XX is the version of the program.)
2. Change directory to the extracted folder:
# cd plcm_drv_v0XX
(0XX is the version of the program.)

Note: Apply our Parallel Text-based LCM to the

environment of virtualization, please use the version 013

or above of the program.

3. Type make to build source code:
# make
After compiling, the executable programs (plcm_test,

plcm_cursor_char, ppdev_test, Test) and the driver

(plcm_drv.ko) will appear in the program’s folder.

Note: The OS supported by Parallel Text-based LCM

function includes platforms based on Linux Kernel series

2.4.x, Linux Kernel series 2.6.x and Linux Kernel series

3.0.x or above.

Install
Install the driver and create a node in the /dev directory

by:

#insmod plcm_drv.ko

#mknod /dev/plcm_drv c 248 0

Note:

If you cannot install the driver,

check whether you have enabled the

parallel port in the BIOS setting .

Once the message of “insmod: error

inserting ‘plcm_drv.ko’: -1 Input/output

error” appears, please check that whether

the major number is repeated or not.

The major number needed with the

mknod command varies with different

software versions; please look up

the Readme file for this value.

Execute
This section contains sample executable programs that

you could test on your platform. It demonstrates some

useful functionality that the LCM provides. Note that the

installation needs to be completed before proceeding

with these executions.
To execute, run the command:
#./plcm_test
Backlight Off/On
turning off/on the backlight of the

LCM display
Display Off turning off the LCM display
Cursor Off/On NOT showing/showing the cursor on the

LCM display
Blinking off/On turning off/on the cursor blinking
Writing “Lanner@Taiwan” displaying the specific

sentences
Reading “Lanner@Taiwan” reading the specific sentence
CGram Test displaying the user-stored characters
Keypad Testing Get the keypad input: the 1st button is

read in as Left, the 2nd button is read in as Up, the 3rd

button is read in as Right, and the 4th button is read in as

Down)