Programming Generation

3 LAN Bypass

The bypass function is used to link two independent

Ethernet ports when the system crashes or powers

off. This means if your system is equipped with a LAN

Bypass function, a condition in your system will not

interrupt your network traffic. Different from the previous

two generations (Gen1 and Gen2), the Lanner Bypass

Gen 3 employs a programming method to control the

bypass function by software. There are typically two

communication status for the bypass function, one is

“Normal” and another is “Bypass” status. Furthermore, the

Lanner Bypass software is capable to control the bypass

status in the following 3 instances.

When the system powers off, it can be forced to

1.

enable the LAN Bypass function .
When the system is in the just-on state which is a

2.

brief moment when it powers up .
When the system is running

3.
Please refer to the LAN_Bypass_Watchdog folder on the

Driver and Manual CD.
And the Lanner bypass possess the following features:

Communication through SMBUS (I2C)

1.

Independent bypass status control for each pair up to

2.

a total of 4 pairs
Lanner Bypass Modules can bypass systems Ethernet

3.

ports on a host system during three instances: Just-on

(Just-on is the brief moment when the internal power

supply turns on and booting process starts), system

off, or upon software request (during run-time).
Software programmable bypass or normal mode

4.

Software programmable timer interval:

5.

- JUST-ON watchdog timer, used during JUST-ON, has

timer setting of 5~1275 seconds of timer interval.
- Run-Time watchdog timer, used during run-time, has

setting of 1~255 seconds of timer interval.

Multiple Watchdog Timers:

6.

-Two for run-time: It is designed to give you a more

variety of controls of the bypass on port basis. By

using dedicated watchdogs for different pairs of

bypass, you have the flexibility to manage the bypass

status for them differently.
-One for just-on: It is designed to give you the

precise control of the bypass during this phase. You

can use this timer to delay enabling the bypass in

just-on state.

For sample LAN bypass code and the Bypass Manual, see

the LAN_Bypass folder on the Driver and Manual CD or

the Lanner Support Website at

http://www.lannerinc.com/

download-center/

. And browse the download center and

look for Lanner LAN Bypass Watchdog User Manual under

the Accessories folder.
Fro a description of the physical LAN ports equipped

with this function, refer to Front Panel Features in Chapter

1 Introduction.