Appendix A:

Programming Watchdog

Timer

A watchdog timer is a piece of hardware that can be

used to automatically detect system anomalies and reset

the processor in case there are any problems. Generally

speaking, a watchdog timer is based on a counter that

counts down from an initial value to zero. The software

selects the counter’s initial value and periodically restarts

it. Should the counter reach zero before the software

restarts it, the software is presumed to be malfunctioning

and the processor’s reset signal is asserted. Thus, the

processor will be restarted as if a human operator had

cycled the power.
For sample watchdog code, see watchdog folder on the

Driver and Manual CD

To execute the sample code: enter the number of

seconds to start count down before the system can be

reset. Press start to start the counter and stop to stop the

counter..
Dwd_tst --swt xxx (Set Watchdog Timer 1-255 seconds)
wd_tst[*] --start (Start Watchdog Timer)
wd_tst --stop (Stop Watchdog Timer)
For sample watchdog code, see watchdog folder on the

Driver and Manual CD

Appendix B:

Setting up Console

Redirections

Console redirection lets you monitor and configure a

system from a remote terminal computer by re-directing

keyboard input and text output through the serial port.

This following steps illustrate how to use this feature. The

BIOS of the system allows the redirection of console I/O

to a serial port. With this configured, you can remotely

access the entire boot sequence through a console port.

Connect one end of the console cable to console

1.

port of the system and the other end to serial port of

the Remote Client System.
Configure the following settings in the BIOS Setup

2.

menu:

BIOS > Advanced > Remote Access Configuration >

Serial Port Mode > [115200, 8 , n ,1 ]

Configure Console Redirection on the client system.

3.

The following illustration is an example on Windows

platform:

A. Click the start button, point to Programs >

a.

Accessories > Communications and select Hyper

Terminal.
B. Enter any name for the new connection and

b.

select any icon.
Click OK.

c.

From the “Connect to”. Pull-down menu, select the

d.

appropriate Com port on the client system and

click OK.
Select 115200 for the Baud Rate, None. for Flow

e.

contorl, 8 for the Data Bit, None for Parity Check,

and 1 for the Stop Bit.