Bios Settings

Chapter 4

Network Application Platforms

Option

Description

3E8/IRQ4

Set this value to allow the serial port to use 3E8
as its I/O port address and IRQ 4 for the interrupt
address. If the system will not use a serial device,
it is best to set this port to Disabled.

2E8/IRQ3

Set this value to allow the serial port to use 2E8
as its I/O port address and IRQ 3 for the interrupt
address. If the system will not use a serial device,
it is best to set this port to Disabled.

Parallel Port Address

This option specifies the I/O address used by the parallel

port. The Optimal setting is 378. The Fail-Safe setting is

Disabled.

Option

Description

Disabled

Set this value to prevent the parallel port from
accessing any system resources. When the value
of this option is set to Disabled, the printer port
becomes unavailable.

378

Set this value to allow the parallel port to use 378
as its I/O port address. This is the default setting.
The majority of parallel ports on computer
systems use IRQ7 and I/O Port 378H as the
standard setting.

278

Set this value to allow the parallel port to use 278
as its I/O port address.

3BC

Set this value to allow the parallel port to use 3BC
as its I/O port address.