beautypg.com

2 summary of the components, Summary of the components, 1 connection box – KACO Powador-gridsave User Manual

Page 9: 2 energy management system

background image

Description

Operating instructions Powador-gridsave_EN

Page 9

3.2

Summary of the components

3.2.1 Connection box

ON

OFF

Powador Protect

off

off

off

B 32A

AC-Circuit Breaker

I

N

=40A

ΔI=300mA

RCCB

off

Test

Typ A

CONNECTION BOX

1

2

3

4

Figure 3: Connection box

Key

Function

1

DC isolator switch

Disconnects the PV generator from the inverter / battery unit

2

Measurement and control

unit

"Powador-protect"

Three-phase monitoring of the grid: switches off the power supply in the

event of impermissible voltage or frequency

3

Circuit breaker

Disconnects the inverter from the AC grid

4

Residual current circuit

breaker

Protects individuals and the installation by isolating the inverter

NOTE

The DC isolator switch, circuit breaker and residual current circuit breaker will switch off the battery

system. Power will then be supplied from the public grid.

3.2.2 Energy management system

Figure 4: Energy management system (EMS) with LCD touchscreen

NOTE

The energy management system (EMS) displays all relevant parameters in order to ensure optimum

operation.