7 maintenance, 1 cleaning the fan, 2 removing the fan – KACO blueplanet 1502xi User Manual
Page 41: Danger, Action
Page 38
38
31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi
Section 7 ·
Maintenance
7 Maintenance
!
DANGER
– Risk of fatal injury by electric shock at live
connections. Lethal voltages are still present in
the inverter and the connection box even after the
electrical connections have been disconnected.
– Wait five minutes before reaching into the
inverter and the connection box.
– When working on the photovoltaic modules, the
current must be switched off on the inverter and
the solar installation with the aid of the AC/DC
disconnect switch on the connection box.
ACTION
Switch off the line voltage and the solar generator with the
aid of the AC/DC disconnector (I = on or energized / O =
off or deenergized).
7.1 Cleaning the fan
If the fan is only covered with loose dust, it can be cleaned with
the help of a vacuum cleaner or a soft brush.
If the fan is very dirty, or if it s defective, it can be removed.
7.2 Removing the fan
If the fan is very dirty or defective, proceed as follows:
!
DANGER
Danger due to lethal voltages.
1.
Switch the DC/AC disconnect to the OFF (0) position to
de-energize the inverter and lock out to prevent inadvertent
energizing of the inverter during service.
2. Wait 5 minutes for the internal components of the
inverter to discharge.
3.
Remove the two inverter hinged door screws and open
door.
4.
Disconnect the fan connections
5HWXUQ 5HWXUQ
5HWXUQ
+RW
+RW
+RW
*1'
*1'
*1'
1
/
/