beautypg.com

7 maintenance, 1 cleaning the fan, 2 removing the fan – KACO blueplanet 1502xi User Manual

Page 41: Danger, Action

background image

Page 38

38

31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi

Section 7 ·

Maintenance

7 Maintenance

!

DANGER

Risk of fatal injury by electric shock at live

connections. Lethal voltages are still present in

the inverter and the connection box even after the

electrical connections have been disconnected.

Wait five minutes before reaching into the

inverter and the connection box.

When working on the photovoltaic modules, the

current must be switched off on the inverter and

the solar installation with the aid of the AC/DC

disconnect switch on the connection box.

ACTION

Switch off the line voltage and the solar generator with the
aid of the AC/DC disconnector (I = on or energized / O =
off or deenergized).

7.1 Cleaning the fan

If the fan is only covered with loose dust, it can be cleaned with
the help of a vacuum cleaner or a soft brush.

If the fan is very dirty, or if it s defective, it can be removed.

7.2 Removing the fan

If the fan is very dirty or defective, proceed as follows:

!

DANGER

Danger due to lethal voltages.

1.

Switch the DC/AC disconnect to the OFF (0) position to

de-energize the inverter and lock out to prevent inadvertent
energizing of the inverter during service.

2. Wait 5 minutes for the internal components of the
inverter to discharge.

3.

Remove the two inverter hinged door screws and open

door.

4.

Disconnect the fan connections

5HWXUQ 5HWXUQ

5HWXUQ

+RW

+RW

+RW

*1'

*1'

*1'

1

/

/