5 installation and start-up, 1 selecting an appropriate place for installation, Installation and start-up – KACO blueplanet 1502xi User Manual
Page 25: Warning, Caution

Page 22
22
31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi
Figure 5.1 (C): Inverter right view dimensions
Model
X
Y
Z
1502xi
4
19
/
32
“
3“
4
13
/
32
“
2502xi
4
19
/
32
“
3“
4
13
/
32
“
3502xi
4
19
/
32
“
3“
6“
5002xi
4
19
/
32
“
3“
6“
Figure 5.1 (D): Inverter back plate access dimensions
Model
X
Y
Z
1502xi
6
3
/
16
“
3
3
/
32
“
3“
2502xi
6
3
/
16
“
3
3
/
32
“
3“
3502xi
6
3
/
16
“
3
3
/
32
“
3“
5002xi
6
3
/
16
“
3
3
/
32
“
3“
Section 4 ·
Unit Description
Section 5 ·
Installation and Start-Up
5 Installation and Start-Up
!
WARNING
Risk of fatal injury from fire or explosions. The
blueplanet’s housing may become hot during
operation.
– Do not mount the blueplanet on flammable
materials.
– Do not install the blueplanet in areas which
contain highly flammable materials.
– Do not install the blueplanet in areas where there
is a risk of explosion.
!
CAUTION
Risk of burns from hot housing components.
Install the blueplanet so that unintentional contact
with heat sink is not possible.
5.1 Selecting an appropriate place for
installation
NOTE
blueplanet inverters meet the requirements of protection
class NEMA 3R if all cable feedthroughs are used or
appropriately sealed.
The units should be installed in areas that are as dry as possible
in order to extend their service life. It is recommended that
the units are installed in climate-controlled areas in order to
protect them from overheating. This also extends their service
life.
The following items are important when you select the place
of installation for the inverter:
– Ensure good access to the unit for installation or any service
work that may later be required.
– Maintain the following minimum clearances
around the unit:
7
7/8
” side clearance to other units,
27
1/2
” clearance to other stacked units,
19
5/8
” clearance to cabinets, ceilings and
above unit,
36” from bottom of connection box to ground
when mounted outdoors.
X
Z
Y
X