beautypg.com

Negative grounded system (factory default), Positive grounded system – KACO blueplanet 1502xi User Manual

Page 32

background image

Page 29

29

31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi

White

Black

Negative Grounded System (Factory Default)

– Connect the positive PV generator connection to Hot in the

connection box.

– Connect the negative PV generator connection to Return in

the connection box.

See diagram in 5.8
No modifications should be made to the inverter. In this
configuration the Negative of the PV generator is grounded
through the GFDI fuse.

5HWXUQ 5HWXUQ

5HWXUQ

+RW

+RW

+RW

*1'

*1'

*1'

1

/

/

Figure 5.7: DC connection of the connection box

– Negative Grounding System

NOTE

In this configuration the Negative of the PV generator is
connected to the ‘Ret’ (Return) terminal and is grounded
through the GFDI fuse. The positive is connected to the
“Hot Terminal”.

Figure 5.8: DC connection 02xi series

-Negative Grounding System

Section 5 ·

Installation and Start-Up

Positive Grounded System

– Connect the negative generator connection to Hot in the

connection box.

– Connect the positive generator connection to Return in the

connection box.

– Connect Return (white cable) to DC+ in the inverter.

– Connect Hot (black cable) to DC- in the inverter.
See diagram in figure 5.10

5HWXUQ 5HWXUQ

5HWXUQ

+RW

+RW

+RW

*1'

*1'

*1'

1

/

/

Figure 5.9: DC connection of the connection box

– Positive Grounding System

NOTE

In this configuration the Positive of the PV generator is
connected to the ‘Ret’ (Return) terminal and is grounded
through the GFDI fuse. The negative is connected to the
‘Hot’ Terminal.

Figure 5.10: DC connection 02xi series

-Positive Grounding System

White

Black

Negative

Positive

Negative

Positive

This manual is related to the following products: