KACO blueplanet 1502xi User Manual
Page 22

Page 19
19
31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi
Inverter – Mechanical and technical data
Model
1502xi
2502xi
3502xi
5002xi
Visual displays
LEDs: PV generator (green)
Grid-feed (green)
Fault (red)
LCD (2 x 16 characters)
Controls
2 keys for display operation and configuration of parameters
AC/DC cut-off point
Pre-installed and separable AC/DC rotary disconnect switch
Connections
Screw compression terminals in the connection box
Cable connection via conduit fittings using 3/4” or 1/2” knockouts on connection box
Terminals accept AWG 4 to AWG 12, 75’C, copper wire. Torque to 20lb-in (2.2N-m).
Interfaces
RS485, S0, error transmitting relay
Ambient temperature
–4°F ... +140°F (> 104°F power derating)
–13°F ... +140°F (> 104°F power derating)
Internal Temperature
monitoring
> 158°F temperature-dependent power limiting
> 176°F disconnection from the grid
Max. humidity
95% (not-condensing)
Cooling
Free convection (no fan
)
5002xi: Free convection (fan assist)
Protection class
NEMA-3R
Noise emission
< 35 dB (noiseless)
5002xi: <45dB (fan operation)
Housing
Aluminium wall-mounted housing
Dimensions W x D x H
30 x 14 x 8
1/4
in.
32 x 14 x. 8
1/4
in.
35 7/8 x 14 x 9
1/2
in.
35 7/8 x 14 x 9
1/2
in.
Weight
42 lbs
52 lbs
69 lbs
70 lbs
Section 3 ·