beautypg.com

KACO blueplanet 1502xi User Manual

Page 22

background image

Page 19

19

31000770-02-112609 blueplanet Operating and Installation Instructions 1502xi - 5002xi

Inverter – Mechanical and technical data

Model

1502xi

2502xi

3502xi

5002xi

Visual displays

LEDs: PV generator (green)

Grid-feed (green)
Fault (red)

LCD (2 x 16 characters)

Controls

2 keys for display operation and configuration of parameters

AC/DC cut-off point

Pre-installed and separable AC/DC rotary disconnect switch

Connections

Screw compression terminals in the connection box

Cable connection via conduit fittings using 3/4” or 1/2” knockouts on connection box

Terminals accept AWG 4 to AWG 12, 75’C, copper wire. Torque to 20lb-in (2.2N-m).

Interfaces

RS485, S0, error transmitting relay

Ambient temperature

–4°F ... +140°F (> 104°F power derating)

–13°F ... +140°F (> 104°F power derating)

Internal Temperature
monitoring

> 158°F temperature-dependent power limiting

> 176°F disconnection from the grid

Max. humidity

95% (not-condensing)

Cooling

Free convection (no fan

)

5002xi: Free convection (fan assist)

Protection class

NEMA-3R

Noise emission

< 35 dB (noiseless)

5002xi: <45dB (fan operation)

Housing

Aluminium wall-mounted housing

Dimensions W x D x H

30 x 14 x 8

1/4

in.

32 x 14 x. 8

1/4

in.

35 7/8 x 14 x 9

1/2

in.

35 7/8 x 14 x 9

1/2

in.

Weight

42 lbs

52 lbs

69 lbs

70 lbs

Section 3 ·

Technical Data

This manual is related to the following products: