Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors MECHATROLINK-III Communications Reference User Manual
Page 345

10 Appendix
10.1.2 Parameters
10-14
Pn230
2
Position Control Expanded
Function Switch
0000 to 0001
–
0000
After reset
Setup
–
5.8.6
Pn231
4
Backlash Compensation
Value
-500000 to
500000
0.1
reference
unit
0
Immediately
Setup
–
5.8.6
Pn233
2
Backlash Compensation Time
Constant
0 to 65536
0.01 ms
0
Immediately
Setup
–
5.8.6
Pn281
2
Encoder Output Resolution
1 to 4096
1 edge/
pitch
20
After restart
Setup
−
8.3.3
Pn304
2
JOG Speed
0 to 10000
1 min
-1
500
Immediately
Setup
−
6.3
Pn305
2
Soft Start Acceleration Time
0 to 10000
1 ms
0
Immediately
Setup
−
−
Pn306
2
Soft Start Deceleration Time
0 to 10000
1 ms
0
Immediately
Setup
−
Pn310
2
Vibration Detection Switch
0000 to 0002
−
0000
Immediately
Setup
−
−
Pn311
2
Vibration Detection
Sensibility
50 to 500
1%
100
Immediately
Tuning
−
6.16
Pn312
2
Vibration Detection Level
0 to 5000
1 min
-1
50
Immediately
Tuning
−
Pn324
2
Moment of Inertia
Calculating Start Level
0 to 20000
1%
300
Immediately
Setup
−
5.3.2
Pn401
2
Torque Reference Filter Time
Constant
0 to 65535
0.01 ms
100
Immediately
Tun-
ing
−
5.9.3
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When
Enabled
Classi-
fication
Profile
Reference
Section
Backlash Compensation Direction
0
Compensates with a reference in the forward direction.
1
Compensates with a reference in the reverse direction.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Vibration Detection Selection
Reference
Section
0
Does not detect vibration.
6.16
1
Outputs warning (A.911) when vibration is detected.
2
Outputs alarm (A.520) when vibration is detected.
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.