E parameters, F7u parameters 4-12 – Yaskawa F7 Modbus User Manual
Page 51

F7U Parameters 4-12
Table 4.8 – D Parameters
Mode
Name
Addr
Digital Operator
Text
Data
Parameter Range or
Data Description
Inc
Default
Run
V/f
V/f
wPG
OLV
FV
Dep
d6-06
02A5h
FieldForce Limit
100 ~ 400 %
1 %
400 %
NA
NA
A
A
►
E Parameters
Table 4.9 – E Parameters
Mode
Name
Addr
Digital Operator
Text
Data
Parameter Range or
Data Description
Inc
Default
Run
V/f
V/f
wPG
OLV
FV
Dep
E1-01
0300h
Input Voltage
155 ~ 255 VAC
1 VAC
200 VAC
Q
Q
Q
Q
A1-02
0h 50
Hz
1h
60 Hz Saturation
2h
50 Hz Saturation
3h 72
Hz
4h
50 Hz VT1
5h
50 Hz VT2
6h
60 Hz VT1
7h
60 Hz VT2
8h
50 Hz HST1
9h
50 Hz HST2
Ah
60 Hz HST1
Bh
60 Hz HST2
Ch 90
Hz
Dh 120
Hz
Eh 180
Hz
Fh Custom
V/F
E1-03 0302h
V/F
Selection
FFh
Custom w/o limit
1 0fh
Q
Q
NA
NA
A1-03
A1-02
E1-04
0303h
Max Frequency
40.0 ~ 400.0 Hz
0.1 Hz
60.0 Hz
Q
Q
Q
Q
A1-02
E1-05
0304h
Max Voltage
0.0 ~ 255.0 VAC
0.1 VAC
230.0 VAC
Q
Q
Q
Q
A1-02
E1-06
0305h
Base Frequency
0.0 ~ 400.0 Hz
0.1 Hz
60.0 Hz
Q
Q
Q
Q
A1-02
E1-07
0306h
Mid Frequency A
0.0 ~ 400.0 Hz
0.1 Hz
3.0 Hz
A
A
A
NA
A1-02
E1-08
0307h
Mid Voltage A
0.0 ~ 255.0 VAC
0.1 VAC
13.0 VAC
A
A
A
NA
A1-02
E1-09
0308h
Min Frequency
0.0 ~ 400.0 Hz
0.1 Hz
1.5 Hz
Q
Q
Q
A
A1-02
E1-10
0309h
Min Voltage
0.0 ~ 255.0 VAC
0.1 VAC
9.0 VAC
A
A
A
NA
A1-02
E1-11
030Ah
Mid Frequency B
0.0 ~ 400.0 Hz
0.1 Hz
0.0 Hz
A
A
A
A
A1-02
E1-12
030Bh
Mid Voltage B
0.0 ~ 255.0 VAC
0.1 VAC
0.0 VAC
A
A
A
A
A1-02
E1-13
030Ch
Base Voltage
0.0 ~ 255.0 VAC
0.1 VAC
230.0 VAC
A
A
Q
Q
A1-02
E2-01
030Eh
Motor Rated FLA
0.1 ~ 1500.0 A
0.1 A
14.0 A
Q
Q
Q
Q
o2-04
E2-02
030Fh
Motor Rated Slip
0.0 ~ 20.0 Hz
0.01 Hz
3.3 Hz
A
A
A
A
E2-03
0310h
No-Load Current
0.0 ~ 1500.0 A
0.1 A
4.5 A
A
A
A
A
o2-04
E2-04
0311h
Number of Poles
2 ~ 48
1
4
NA
Q
NA
Q
E2-05
0312h
Term Resistance
0.0 ~ 65.0 Ohm
0.1 Ohm
0.771 Ohm
A
A
A
A
E2-06
0313h
Leak Inductance
0.0 ~ 40.0 %
0.1 %
19.60 %
NA
NA
A
A
E2-07
0314h
Saturation Comp1
0.0 ~ 0.5
0.01
0
NA
NA
A
A
E2-08
0315h
Saturation Comp2
0.0 ~ 0.75
0.01
0
NA
NA
A
A
E2-09
0316h
Mechanical Loss
0.0 ~ 10.0 %
0.1 %
0.00 %
NA
NA
A
A
E2-10
0317h
Tcomp Iron Loss
0 ~ 65535 W
1 W
0 W
A
A
NA
NA
E2-11
0318h
Mtr Rated Power
0.0 ~ 650.0 kW
0.01 kW
0.4 kW
Q
Q
Q
Q
E2-12
0328h
Saturation Comp3
1.3 ~ 1.6
0.01
1.3
NA
NA
A
A
0 V/f
1
V/f w/ PG
2
Open Loop Vector(OLV)
E3-01 0319h Control
Method
3
Flux Vector (FV)
1
2
A A A A
E3-02
031Ah
Max Frequency
40.0 ~ 400.0 Hz
0.1 Hz
60.0 Hz
A
A
A
A
E3-03
031Bh
Max Voltage
0.0 ~ 255.0 VAC
0.1 VAC
230.0 VAC
A
A
A
A
E3-01
E3-04
031Ch
Base Frequency
0.0 ~ 400.0 Hz
0.1 Hz
60.0 Hz
A
A
A
A
E3-05
031Dh
Mid Frequency
0.0 ~ 400.0 Hz
0.1 Hz
3.0 Hz
A
A
A
NA
E3-06
031Eh
Mid Voltage
0.0 ~ 255.0 VAC
0.1 VAC
10.0 VAC
A
A
A
NA
E3-01
E3-07
031Fh
Min Frequency
0.0 ~ 400.0 Hz
0.1 Hz
0.5 Hz
A
A
A
A
E3-08
0320h
Min Voltage
0.0 ~ 255.0 VAC
0.1 VAC
1.7 VAC
A
A
A
NA
E3-01
E4-01
0321h
Motor Rated FLA
0.0 ~ 1500.0 A
0.1 A
0.0 A
A
A
A
A
o2-04
E4-02
0322h
Motor Rated Slip
0.0 ~ 20.0 Hz
0.01 Hz
0.0 Hz
A
A
A
A
E4-03
0323h
No-Load Current
0.0 ~ 1500.0 A
0.1 A
0.0 A
A
A
A
A
o2-04
E4-04
0324h
Number of Poles
2 ~ 48
1
4
NA
A
NA
A
E4-05
0325h
Term Resistance
0.0 ~ 65.0 Ohm
0.1 Ohm
0.0 Ohm
A
A
A
A
E4-06
0326h
Leak Inductance
0.0 ~ 40.0 %
0.1 %
0.00 %
NA
NA
A
A
E4-07
0327h
Mtr Rated Power
0.0 ~ 650.0 kW
0.01 kW
0.4 kW
A
A
A
A