beautypg.com

Yaskawa Motion Control G7 Drive Software User Manual

Page 23

background image

Date: 05/16/08, Rev: 08-05

Page 23 of 38

TM.G7SW.117

Figure 9: Typical move profile from “home” to a positive position, move command type – Rising Edge

(P1-03 = 1)

Figure 10: Typical move profile from “home” to a positive position, move command type – Falling Edge

(P1-03 = 2)

Digital
Inputs

Motor

Speed

Digital

Outputs

Run Cmd

Move Cmd

During Move

Move Complete

At Home

Selected

Accel

Rate

Selected

Decel

Rate

Selected

Max.

Speed

In Position

Window

(P1-08)

In Position

Window

(P1-08)

Positioning

Speed

(Determined

Automatically)

0 Hz

60 Hz

Digital
Inputs

Motor

Speed

Digital

Outputs

Run Cmd

Move Cmd

During Move

Move Complete

At Home

Selected

Accel

Rate

Selected

Decel

Rate

Selected

Max.

Speed

In Position

Window

(P1-08)

In Position

Window

(P1-08)

Positioning

Speed

(Determined

Automatically)

0 Hz

60 Hz