beautypg.com

Yaskawa GPD 515-G5 Modbus RTU User Manual

Page 42

background image

7-6

Registers

Monitor Registers (continued)

REGISTER

FUNCTION

BIT

DESCRIPTION

(in hex)

NO.

018h

CPF Content 2

0

CPF20 Fault

1

CPF21 Fault

2

CPF22 Fault

3

CPF23 Fault

4-15

not used

019h

Minor Fault Content 1

0

Undervoltage Detection (UV)

1

Overvoltage Detection (oV)

2

Heatsink Overtemperature (oH)

3

Drive Overheat Alarm (oH1)

4

Overtorque 1 Detection (oL3)

5

Overtorque 2 Detection (oL4)

6

2-wire Sequence Input Fault (EF)

7

During External Baseblock (BB)

8

External Fault 3 (EF3)

9

External Fault 4 (EF4)

10

External Fault 5 (EF5)

11

External Fault 6 (EF6)

12

External Fault 7 (EF7)

13

External Fault 8 (EF8)

14

Cooling Fan Fault (FAN)

15

Overspeed (oS)

01Ah

Minor Fault Content 2

0

Speed Deviation (DEV)

1

PG Open (PGo)

2

Operator Disconnected (OPR)

3

Modbus Communication Error (CE)

4

not used

5

not used

6

Motor Overload (oL1)

7

Drive Overload (oL2)

8-15

not used

This manual is related to the following products: