5 Mechanical Installation

20

YASKAWA ELECTRIC TOBP C720600 01C 1000-Series Option CDBR-†D, LKEB-† Installation Manual

Installation Environment

Install the CDBR Braking Unit in an environmental matching the specifications below.

UL and CE Compliance

Place the braking unit within an appropriate enclosure suitable to its environment for

compliance with UL and CE standards. Install unit in a pollution degree 2 environment or

equivalent according to UL standards.
For main circuit terminal wiring ( , , B1, B2), UL approval requires using UL Listed

copper wires (rated at 75

°C (167°F)).

Environment

Conditions

Installation Area

Indoors

Ambient Temperature

IP00, IP20: -10 to +50

°C (14 to +122°F)

NEMA Type 1: -10 to +40

°C (14 to +104°F)

Storage Temperature

-20 to +60

°C (-4 to +140°F) (short-term temperature during transportation)

Humidity

95% RH or less and free of condensation

Surrounding Area

Install the option in an area free from:

• oil mist and dust
• metal shavings, oil, water, or other foreign materials
• radioactive materials
• combustible materials (e.g., wood)
• harmful gases and liquids
• excessive vibration
• chlorides
• direct sunlight

Altitude

Up to 1000 m (3280 ft) without derating; up to 3000 m (9842 ft) with output and current
derating. Contact Yaskawa or your nearest sales representative for applications above
1000 m (3280 ft).

Vibration/Shock

10 to 20 Hz: 9.8 m/s

2

, 20 to 55 Hz: 5.9 m/s

2

Installation Orientation Install the option upright to maintain proper cooling.

TOBP_C720600_01C_3_0_E.fm 20 ページ 2013年10月7日 月曜日 午後2時20分