65

OV

Overvoltage

Overvoltage (OV)

The main circuit direct current voltage
exceeded the OV level.
Detection level
230 V class: Approx. 410 V
460 V class: Approx. 820 V
575 V class: Approx. 1040 V

Extend the deceleration time,
add braking circuit.

A

SC

Short Circuit

Load short-circuit (SC) Inverter output (load) is short-circuited.

·Check the motor coil resis-

tance.

·Check the motor installation.

A

PUF

DC Bus Fuse Open

Fuse blown (FU)

·The DC bus fuse is blown.
·The output transistors were damaged.

Check for damaged transis-
tor, load side short circuit,
grounding, etc.

A

OH

Heatsink Over tmp

Heatsink overheat
(OH1)

The transistor heatsink temperature
exceeded the allowable value.

Check the fan and ambient
temperature.

A

OL1

Motor Overloaded

Motor overload (OL1)

Inverter output exceeded the motor
overload level.

Reduce the load.

A

OL2

Inv Overloaded

Inverter overload (OL2)

Inverter output exceeded the inverter
overload level.

Reduce the load, extend the
acceleration time.

A

PF

Input Pha Loss

Input open-phase

Inverter input power supply has open
phase.
Large unbalance in input voltage.

·Check the line voltage.
·Re-tighten the input terminal

screws.

A

LF

Output Pha Loss

Output open-phase

Inverter output has open-phase.

·Check the output wiring.
·Check the motor imped-

ance.

·Re-tighten the output termi-

nal screws.

A

RR

Dyn Brk Transistr

Braking transistor fail-
ure

The braking transistor has failed.

The inverter requires repair.

A

RH

Dyn Brk Resistor

Braking resistor unit
overheat

The braking resistor unit temperature
has exceeded the allowable value.
(Protects only inverter built-in type)

Reduce the regenerative
load.

A

OS

Over speed

Overspeed (OS)

The motor speed exceeded the over-
speed level.

--

A

PGO

PG open

PG open circuit (PGO) The PG line is broken.

·Check the PG line.
·Check the condition of the

motor lock or the load.

A

DEV

Speed Deviation

Speed deviation (DEV)

The deviation of the speed reference
and speed feedback exceeded the
regulation level.

Check the load.

B

EF

External Fault

Simultaneous forward/
reverse run commands

Both FWD and REV run commands
are simultaneously input for 500ms or
longer.

Check sequence circuit.

B

BB

Base Block

External baseblock

External baseblock command is input
from control circuit terminal.

Check sequence circuit.

B

Fault Display

Name

Description

Corrective Action

Class

Chapter 4 - Diagnostics

Alarm & Fault Displays