Table 4. MicroTrac Hub Card Setup

CR1

bnc1 MicroTrac LAN port is active

(red)

(used either as the input or one of the outputs)

CR2

bnc2 MicroTrac LAN port is active

(red)

(used either as the input or one of the outputs)

LEDs

CR3

bnc3 MicroTrac LAN port is active

(red)

(used either as the input or one of the outputs)

CR4

bnc4 MicroTrac LAN port is active

(red)

(used either as the input or one of the outputs)

CR5

signals reconfigure on the MicroTrac LAN

(yellow)

(light on when reconfiguring)

CR6

LAN timing light – usually on

(red)

(if off, problem with LAN timing)

E1

e

enables LAN driver (default)

d

disables LAN driver (used during testing)

m

select Hub card as master (default)

E4

s

select Hub card as slave
(used when connecting more than one card together)

E6

e

enables LAN driver (default)

Jumpers

d

disables LAN driver (used during testing)

con

selects top connector (conn)

E8

for master/slave timing signals (default)

bus

selects the computer bus for master/slave timing signals

conv

converts the +5V to –5V for use by the card

E9

when not in the bus configuration

bus

does not convert the +5V to –5V; takes –5V
from computer bus (default)
response time-out (msec)

reconfigure time-out (msec)

nor

74.7

840 (default)

E10

et1

283.4

1680

et2

561.8

1680

et3

1118.6

1680

bnc1-4

MicroTrac LAN connection

Connectors

(used either as the input or one of the outputs)

conn

used to connect other Hub cards together
in the master/slave configuration

2

HARDWARE

7

5/24/96

MicroTrac Hub Card

M i c r o Trac Hub

C a r d

( c o n t i n u e d )

RD 3004-20