Nec hp ratings for 480v normal duty models – Yaskawa GPD506/P5 to P7 User Manual
Page 22

Product Transition Guide
Appendix 1 –Ratings and Heat Loss Comparison
Page
22
of 48
NEC HP Ratings for 480V Normal Duty Models
GPD506/P5 460V Models
P7 480V Models
Variable Torque
(n116=1)
Normal
Duty
(C6-02=2)
NEC
HP
460V
NEC
Amps
GPD506/P5
Model
CIMR-P5U
Output
Amps Fc kHz
OL %
VT
1 minute
P7
Model
CIMR-P7U
Output
Amps
Fc
kHz
Overload %
ND
1 minute
5.0 7.6 43P71 8.5 10 120
43P71 7.6 15 120
44P01 8.7 15 120
7.5 11 44P01 11.7 10 120
45P51 12.5 15
120
10 14 45P51 14.8 10 120
47P51 17 15 120
15 21 47P51 21 10 120
20 27 40111 28.6 10 120
40111 27 8 107
25 34 40151 34 10 120
40151 34 10 109
30 40 40181 41 10 120
40181 40 10 117
40 52 40221 52 8 120
50 65 40301 65 5 120
40301 67.2 8
107
60 77 40371 80 5 120
40371 77 8 117
75 96 40451 96 5 120
40451 96 8 114
100 124 40551 128 5 120
40551 125 5
108
125 156 40751* 180 5 120
40751* 156 5
115
150 180
40901* 180 8
120
200 240 41101* 240 5 120
41101* 240 5
108
41321* 260 5
120
250 302 41601* 302 5 120
41601* 304 5
120
300 361 41850 380 2.5 120
350 414 42200 506 2.5 120
41850 414 2
107
400 477
450 506
42200 506 2
118
500 590 43000 675 2.5 120
550 660
43000 675 2
120
*Note: Optional NEMA1 kit required on these models for NEMA1 rating.