Yaskawa GPD506/P5 to P7 User Manual
Page 11
Product Transition Guide
GPD506/P5 to P7
Page
11
of 48
GPD506/P5 to P7 Specification Differences (continued)
Feature
or Function
Item
Yaskawa GPD506/P5
Yaskawa P7
Design Features (continued)
Common DC Bus Capable
-
No
Yes
DC Link or AC Choke
-
230V: 30HP to 125HP (VT)
460V: 30 to 250HP (VT)
DC Link (Standard)
240V: 30HP to 150 HP
480V: 40 HP to 500 HP
Harmonic Counter Measures
-
12 Pulse: 230V: 30HP and Above
460V: 30HP to 250HP
12 Pulse:
240V: 30HP to 150HP
480V: 40HP to 500HP
Unique Feature/Function
-
-
HSB – High Slip Braking
Inputs and Outputs
Total Qty.
6
7 (optically isolated)
Digital Input Terminal
NPN/PNP NPN Switchable
NPN/PNP
Total Qty
2
3
Digital Output Terminal
Relay Output
1 x Form C, 1 x Form A,
2 x Form A, 1 x Form C
Qty. 2
2
Level Input
0-10V or 4-20mA
0-10 or 4-20mA
Scan Rate
5 msec
5 msec
Analog Input
Loss Detection
Ramp or Continue
Ramp, Coast or Continue
Qty. 1
2
Output Level
0-10V
0-10V or 4-20ma
With independent level selections
Analog Output
Resolution
9 bit
10 bit plus sign
Service Conditions
Rated Input
-
3-phase, 200-230Vac
3-phase, 380-460Vac
Tolerance +10 to –15%
3-phase,500-600Vac
Tolerance +10 to –10%
Frequency: 50/60 Hz +/- 5%
3-phase, 200-240Vac
3-phase, 380-480Vac
Tolerance +10 to –15%
Frequency: 50/60 Hz +/- 5%
Note: P7 Models 2037-2110 rated
for 200-230Vac.
Ambient Temperature
ºC
(IP21/NEMA1)
-10ºC ~ +40ºC
(IP00/Protected Chassis)
-10ºC ~ +45ºC
-10ºC ~ +40ºC (IP21/NEMA1)
-10ºC ~ +45ºC
(IP00/Protected Chassis)
(Automatic OL protection curve
based on ambient temperature
setting of L8-12)
Storage Temperature
ºC
-10ºC ~ +60ºC
-20ºC ~ +60ºC
NEMA 4X
Optional
N/A
Enclosure Types
NEMA 3/3R
Optional
N/A