SMA SB 3000TL User Manual
Page 49
![background image](https://www.manualsdir.com/files/818246/content/doc049.png)
SB 4000TL-21
SB 5000TL-21
Initial input voltage
150 V
150 V
Maximum input current, input A
15 A
15 A
Maximum input current, input B
15 A
15 A
Maximum short-circuit current per input*
20 A
20 A
Maximum reverse current from the inverter in the
system for max. 1 ms
0 A
0 A
Number of independent MPP inputs
2
2
Strings per MPP input
2
2
Overvoltage category in accordance with
IEC 60664-1
II
II
* In accordance with IEC 62109-2: I
SC PV
AC Output
SB 4000TL-21
SB 5000TL-21
Rated power at 230 V, 50 Hz
4,000 W
4,600 W
Maximum apparent AC power
4,000 VA
5,000 VA
Rated grid voltage
230 V
230 V
Nominal AC voltage
220 V / 230 V /
240 V
220 V / 230 V /
240 V
AC voltage range*
180 V to 280 V
180 V to 280 V
Nominal AC current at 220 V
18.2 A
20.9 A
Nominal AC current at 230 V
17.4 A
20.0 A
Nominal AC current at 240 V
16.7 A
19.2 A
Maximum output current
22 A
22 A
Total harmonic distortion of the output current
with total harmonic distortion of the AC voltage
< 2%, and AC power > 50% of the rated power
≤4%
≤4%
Inrush current
< 20% of the nominal
AC current for a
maximum of 10 ms
< 20% of the nominal
AC current for a
maximum of 10 ms
Maximum output current under fault conditions
34 A
34 A
Rated power frequency
50 Hz
50 Hz
AC power frequency*
50 Hz / 60 Hz
50 Hz / 60 Hz
Operating range at AC power frequency 50 Hz
45 Hz to 55 Hz
45 Hz to 55 Hz
11 Technical Data
SMA Solar Technology AG
Operating Manual
49
SB30-50TL-21-BE-en-11