All BLUETOOTH devices in a PV system must have the same NetID. You can set a new NetID in the
inverter by means of the rotary switch C.

Figure 8: Positions of rotary switch C

Position

Explanation

0

Communication via BLUETOOTH is deactivated.

1

Communication via BLUETOOTH with a further BLUETOOTH device

2 to F

NetID for communication via BLUETOOTH with multiple BLUETOOTH devices

Procedure:

1.

Danger to life due to high voltages

• Ensure that the inverter is disconnected from all voltage sources (see Section 10, page 45

).

2. To set a new NetID, set the rotary switch C to the

determined NetID using a flat-blade screwdriver
(blade width: 2.5 mm).

3. To deactivate communication via BLUETOOTH,

set the rotary switch C to position 0 using a flat-
blade screwdriver (blade width: 2.5 mm). This
will protect your PV system from unauthorized
access.

☑ The inverter will adopt the setting after commissioning. This can take up to five minutes.