beautypg.com

Editing the table format – HEIDENHAIN TNC 640 (34059x-05) ISO programming User Manual

Page 404

background image

Programming: Special functions

11.7

Freely definable tables

11

404

TNC 640 | User's ManualDIN/ISO Programming | 1/2015

Editing the table format

Press the

EDIT FORMAT soft key (shift the soft-key row): The

TNC opens the editor form, in which the table structure is

shown. The meanings of the structure commands (header

entries) are shown in the following table.

Structure
command

Meaning

Available columns:

List of all columns contained in the table

Move before:

The entry highlighted in

Available

columns is moved in front of this

column

Name

Column name: Is displayed in the header

Column type

TEXT: Text entry

SIGN: Sign + or -

BIN: Binary number

DEC: Decimal, positive, complete

number (cardinal number)

HEX: Hexadecimal number

INT: Complete number

LENGTH: Length (is converted in inch

programs)

FEED: Feed rate (mm/min or 0.1 inch/

min)

IFEED: Feed rate (mm/min or inch/min)

FLOAT: Floating-point number

BOOL: Logical value

INDEX: Index

TSTAMP: Fixed format for date and time

Default value

Default value for the fields in this column

Width

Width of the column (number of

characters)

Primary key

First table column

Language-sensitive

column name

Language-sensitive dialogs