beautypg.com

Activating and deactivating collision monitoring, See "activating and – HEIDENHAIN TNC 640 (34059x-05) ISO programming User Manual

Page 382

background image

Programming: Special functions

11.2

Dynamic Collision Monitoring (Option #40)

11

382

TNC 640 | User's ManualDIN/ISO Programming | 1/2015

Activating and deactivating collision monitoring

In some cases it is necessary to temporarily deactivate collision

monitoring:

To reduce the distance between two objects monitored for

collision
To prevent stops during program runs

Danger of collision!

If you deactivate collision monitoring, the TNC does

not output an error message with a pending collision.
Also, with inactive collision monitoring, the TNC does

not prevent movements caused by collision.

Permanently manually activating and deactivating collision
monitoring

Select the

Manual operation or Electronic

handwheel mode of operation

Shift the soft-key row if necessary

Press the

COLLISION soft key

Select the operating modes for which the

modification should apply:

Program run: Positioning with manl.data

input, Program run, single block and Program

run, full sequence
Manual Operation
: Manual operation and

Electronic handwheel

Press the

GO TO key

Select the condition for which the selected

operating modes should apply:

Inactive: Deactivate collision monitoring
Active: Activate collision monitoring

Press the

OK soft key.