Copying system data to a string parameter, 9 str ing p a ra met e rs – HEIDENHAIN iTNC 530 (340 49x-06) ISO programming User Manual
Page 290
![background image](https://www.manualsdir.com/files/816400/content/doc290.png)
290
Programming: Q Parameters
9.9 Str
ing P
a
ra
met
e
rs
Copying system data to a string parameter
With the SYSSTR function you can copy system data to a string
parameter. At present only reading of the system time is available.
U
Select Q parameter functions
U
Select the STRING FORMULA function
U
Enter the number of the string parameter in which the
TNC is to save the copied string. Confirm with the
ENT key
U
Select the function for copying system data
U
Enter the Number of the system key (ID321 for the
system time) that you want to copy, and confirm with
the ENT key
U
Enter the Index for system key. It defines the format
for the system time to be output. Confirm with the
ENT key (see description below)
U
Array index of the source to be read
has no
function yet. Confirm with the NO ENT key
U
Number to be converted to text
has no function yet.
Confirm with the NO ENT key
U
Close the parenthetical expression with the ENT key
and confirm your entry with the END key
This function is prepared for future expansions. The
parameters IDX and DAT currently have no function.