beautypg.com

1 principle and overview – HEIDENHAIN iTNC 530 (340 49x-06) ISO programming User Manual

Page 262

background image

262

Programming: Q Parameters

9.1 Pr

inciple and Ov

erview

9.1 Principle and Overview

You can program entire families of parts in a single part program. You
do this by entering variables called Q parameters instead of fixed
numerical values.

Q parameters can represent information such as:

„

Coordinate values

„

Feed rates

„

Spindle speeds

„

Cycle data

Q parameters also enable you to program contours that are defined
with mathematical functions. You can also use Q parameters to make
the execution of machining steps depend on logical conditions.

Q parameters are designated by letters and a number between 0 and
1999. Parameters that take effect in different manners are available.
Please refer to the following table:

Q4

Q2

Q3

Q1

Q5

Q6

Meaning

Range

Freely applicable parameters, as long as no
overlapping with SL cycles can occur, globally
effective for all programs stored in the TNC
memory

Q0

to Q99

Parameters for special TNC functions

Q100

to Q199

Parameters that are primarily used for cycles,
globally effective for all programs stored in the
TNC memory

Q200

to Q1199

Parameters that are primarily used for OEM
cycles, and are globally effective for all programs
stored in the TNC memory. This may require
coordination with the machine manufacturer or
supplier

Q1200

to Q1399

Parameters that are primarily used for call-
active
OEM cycles, globally effective for all
programs that are stored in the TNC memory

Q1400

to Q1499

Parameters that are primarily used for Def-
active
OEM cycles, globally effective for all
programs that are stored in the TNC memory

Q1500

to Q1599

Freely applicable parameters, globally effective
for all programs stored in the TNC memory

Q1600

to Q1999

Freely usable QL parameters, only effective
locally (within a program)

QL0

to QL499

Freely usable QR parameters that are nonvolatile,
i.e. they remain in effect even after a power
interruption

QR0

to QR499