40

Specifications

Housing

ND 730/ND 770
Bench-top design, cast metal
Dimensions (W • H • D)
270 mm x 172 mm x 93 mm

Operating temp.

0° to 45° C (32° to 113° F)

Storage temp.

–20° to 70° C (–4° to 158°F)

Weight

Approx. 2.3 kg

Relative humidity

<75% annual average
<90% in rare cases

Power supply

100 Vac to 240 Vac (-15% to +10%)
50 Hz to 60 Hz (

± 2 Hz)

Power consumption

15 W

Protection

IP40 according to EN 60 529

Encoder inputs

For encoders with
7 to 16 µA

PP

Grating period 2, 4, 10, 20, 40, 100,
200 µm and 12.8 mm
Reference-mark evaluation for
distance-coded and single reference
marks.

Input frequency

Max. 100 kHz
with 30 m (66 ft) cable

Display step

Adjustable
(see "Linear Encodes")

Tool datums

9 (nonvolatile)

Functions

− Distance-to-go display

− Radius/diameter display

− Separate value/sum display

(only ND 770)

− Hold position

− Set absolute datum

− Taper calculator

− Scaling factor

Specifications

730_770t4.pm6

21.07.2004, 08:38

40