Mounting

To mount the display unit on a support, use the M4 threaded holes in
the rubber feet. You can also mount the display unit on the optional
tilting base.

VRZ0702

HEIDE

NHAIN

Tilting base

Support

Power Connection

Power leads and
Connect protective ground to

Power supply:

100 Vac to 240 Vac (-15% to +10%)
50 Hz to 60 Hz (

± 2 Hz)

A voltage selector is not necessary.

Danger of electrical shock!
Connect a protective ground. This connection must
never be interrupted.

Unplug the power cord before opening the housing.

To increase the noise immunity, connect the ground terminal
on the rear panel to the central ground point of the machine
(minimum cross-section: 6 mm

2

).

L

N