beautypg.com

Operating parameter list, Operating parameters – HEIDENHAIN ND 730 v.1 User Manual

Page 30

background image

31

List of operating parameters

P1 Unit of measurement

1)

Display in millimeters

MM

Display in inches

INCH

P3.1 to P3.3 Radius/diameter display

1)

Display position value as radius

RADIUS

Display position value as diameter

DIAMETER

P11 Activate scaling factor

1)

Scaling factor active

SCALING ON

Not active

SCALING OFF

P12.1 to P12.3 Enter scaling factor

1)

Enter a scaling factor separately for each axis:
Entry value > 1: workpiece will “grow”
Entry value = 1: workpiece will remain the same size
Entry value < 1: workpiece will “shrink”
Input range:

0.111111 to 9.999999

Factory setting:

1

P30.1 to P30.3

Counting direction

Positive counting direction with
positive direction of traverse

DIRECT. POS

Negative counting direction with
positive direction of traverse

DIRECT. NEG

Operating Parameters

P32.1 to P32.3 Subdivision of the encoder signals

1024 / 1000 / 800 / 512 / 500 / 400 / 256 / 200
128 / 100 / 80 / 64 / 50 / 40 / 20 / 10 / 8 / 5 / 4 / 2 / 1 / 0.8 /
0.5 / 0.4 / 0.2 / 0.1

P33.1 to P33.3 Counting step

0 - 1 - 2 - 3 - 4 - 5 - 6 - 7 - 8 - 9
0 - 2 - 4 - 6 - 8
0 - 5

P38.1 to P38.3 Decimal places

1 / 2 / 3 / 4 / 5 / 6 (up to 8 with inches display)

P40.1 to 40.3 Define axis error compensation

Axis error compensation not active

CORR. OFF

Linear axis error compensation active

CORR. LIN

Multipoint axis error compensation active

CORR. ABS

(See "Multipoint Axis Error Compensation")

1)

User parameter