Operating parameters, Entering/changing operating parameters – HEIDENHAIN ND 730 v.1 User Manual
Page 29
30
Operating Parameters
Operating parameters allow you to modify the operating
characteristics of your display unit and define the evaluation
of the encoder signals. Operating parameters that can be
changed by the user are called user parameters, and can be
accessed with the SPEC FCT key and the dialog PARAMETER
(user parameters are identified as such in the parameter list).
The full range of parameters can only be accessed via the
dialog "CODE" and input of the code number 95148.
Operating parameters are designated by the letter P and a
number. Example: P11. The parameter designation is shown
in the X display when a parameter is selected with the TOOL
and ENT keys.
The parameter setting is shown in the Z = ND 730/
Zo = ND 770 display.
Some operating parameters have separate values for each
axis. Such parameters have an additional index number from
1 to 3 with the ND 770 and from 1 to 2 with the ND 730.
Example:
P12.1 scaling factor, X axis
P12.2 scaling factor Zo axis (only ND 770)
P12.3 scaling factor, Z axis
The operating parameters are preset before the unit leaves
the factory. These factory settings are indicated in the
parameter list in boldface type.
Operating Parameters
Entering/changing operating parameters
Calling operatingparameters
➤
Press the SPEC FCT key
➤
Press SPEC FCT or TOOL until "PARAMETER" is
displayed in X.
➤
Confirm with ENT.
➤
If you wish, use the TOOL key to select the dialog for
entering the code number 95148 to access the full
range of operating parameters.
Scrolling through the operating parameter list
➤
Scroll forwards: Press the ENT key.
➤
Scroll backwards: Press the TOOL key.
Changing parameter settings
➤
Press the minus key or enter the value and confirm
with the ENT key.
Correcting an entry
➤
Press CL. This restores the old value.
Exiting the operating parameters
➤
Press SPEC FCT or CL.