Technical Specifications and
Operating Limits

AC power requirements

If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include ac power distribution that can handle
these values.

Size and weight

Cable lengths

You should use the Fibre Channel cables shipped with your PFR600/E when making
connections.

Any copper cables you use must meet the appropriate standards for 1-Gbit FC-AL loops.
Such cables are fully shielded, twin-axial, full-duplex cables with DB-9 or connectors.
Cables greater than 10 meters must be equalized; cables equal to or less than 10 meters
do not need to be equalized. Do not use copper cables longer than 15 meters for any Fibre
Channel connection in a Profile system.

Any optical cables you use must meet the appropriate standards for 2-Gb/s FC-AL loops.
Such cables are duplex LC cables with lengths up to 300m on 50/125

µ

m MMF, or up to

150m on 62.5/125

µ

m MMF

Power Input

100-120 VAC, 50/60Hz, 6amps

200-240 VAC, 50/60Hz, 3 amps

Item

Measurement

Height

13.34 cm (5.25 in) (3 rack units)

Width

44.83 cm (17.65 in)

Depth

55.88 cm (22 in)

Weight

34.0 kg (75.0 lbs)