Technical specifications and operating limits, Ac power requirements, Size and weight – Grass Valley PFR600/E User Manual
Page 53: Cable lengths, Appendix a, Appendix a, “technical, Specifications and operating limits, Size and weight cable lengths

20 February 2004
PFR600/E Instruction Manual
53
Appendix
A
Technical Specifications and
Operating Limits
AC power requirements
If one of the two power supplies fails, the remaining supply and cord must support the
full load. Your rackmount cabinet must include ac power distribution that can handle
these values.
Size and weight
Cable lengths
You should use the Fibre Channel cables shipped with your PFR600/E when making
connections.
Any copper cables you use must meet the appropriate standards for 1-Gbit FC-AL loops.
Such cables are fully shielded, twin-axial, full-duplex cables with DB-9 or connectors.
Cables greater than 10 meters must be equalized; cables equal to or less than 10 meters
do not need to be equalized. Do not use copper cables longer than 15 meters for any Fibre
Channel connection in a Profile system.
Any optical cables you use must meet the appropriate standards for 2-Gb/s FC-AL loops.
Such cables are duplex LC cables with lengths up to 300m on 50/125
µ
m MMF, or up to
150m on 62.5/125
µ
m MMF
Power Input
100-120 VAC, 50/60Hz, 6amps
200-240 VAC, 50/60Hz, 3 amps
Item
Measurement
Height
13.34 cm (5.25 in) (3 rack units)
Width
44.83 cm (17.65 in)
Depth
55.88 cm (22 in)
Weight
34.0 kg (75.0 lbs)