Chapter 3 Servicing the PFR600 Series RAID

48

PFR 600/E Instruction Manual

20 February 2004

Installing the LBB or RAID Controller

To install the LBB or RAID Controller:

1. Insert the replacement module into the empty bay. Make sure the module is seated.

2. Push up the two ejector levers to seat the module.

3. Tighten the captive screws.

4. Reconnect cabling.

5. Verify module initialization using rear panel status LEDs. Refer to

“Interpreting rear

panel status LEDs” on page 42

.

6. Ensure that the replacement drive firmware matches that of the other controller. Refer

to Chapter 3, “Working with Storage Using GVG Disk Utility”, in the Profile XP
System Guide
for information on checking and loading controller firmware.

7. If installing a RAID controller, configure the network and SNMP settings as

described in the PVS Installation Guide.

8. Check module status using NetCentral or GVG Disk Utility. If required, update the

firmware to match the version on the other RAID controller using GVG Disk Utility.

2921

1

2

3