Grass Valley PFR600/E User Manual
Page 23

PFR600/E circuit board modules
20 February 2004
PFR600/E Instruction Manual
23
When the redundant Fiber Channel option is not installed in the PFR600 RAID
Storage Chassis, only one RAID Controller is installed along with one LBB module
as shown in the following figure. The LBB module and the LBB contained in the
RAID Controller module provide the two LBBs required in the PFR600 Series Fibre
Channel RAID Storage Chassis. The LBB and RAID Controller modules are clearly
labeled on the rear panel of each canister.
An RJ-type connector is provided for Ethernet network connection, which is used for
SNMP monitoring and firmware downloads. A DB-9 serial port is provided for serial
communications with a console program to configure the RAID Controller’s IP
address, subnet mask, SNMP domain, and other network settings. These settings are
required to use the NetCentral monitoring software. Refer to your PVS Series
Installation Guide or the Open SAN Instruction Manual for information how these
connectors are used.
7 Segment LED
(displays chassis address)
7 Segment LED
(displays chassis address)
Serial
Port
Serial
Port
Ethernet
Port
Ethernet
Port
Fibre
Channel
Loop Port
Fibre
Channel
Loop Port
Host Fibre
Channel Port
Loop Bypass Board B
PFR600