Powering-up the PFR 600/E system

20 February 2004

PFR600/E Instruction Manual

37

Powering-up the PFR600/E system

1. Power-up the PFR600E Expansion chassis prior to, or at the same time as the

PFR600 Controller chassis.

NOTE: You must always power-up the PFR600E Expansion chassis prior to, or at
the same time as the PFR600 RAID Controller chassis. Failure to do so may
prevent some LUNs in the expansion chassis from being recognized.

2. Wait for RAID storage initialization, as follows:

- Rear panel 7-segment LED displays the chassis address — approximately two

minutes.

- Wait until all disk access LEDs are steady green— approximately 3 minutes.

- Refer to sections in

Chapter 3, “Servicing the PFR600 Series RAID”

for

information on interpreting status LED behavior.

NOTE: Refer to the Profile XP System Guide or Open SAN Instruction Manual for
complete system power-up procedures.

2915a

7-Segment Display LED