Lbb 7-segment display codes – Grass Valley PFR600/E User Manual
Page 43

LBB 7-segment display codes
20 February 2004
PFR600/E Instruction Manual
43
LBB 7-segment display codes
The following table shows event codes for the rear panel 7-segment display on each
LBB.
Code
Type
Blink Rate
Meaning
0 thru 9
Informational
Steady or
alternating with
other code.
A
Warning
Alternating with
chassis address
Fibre Channel speed has changed. Power cycle of
all connected RAID chassis is required.
C Power-up
Steady
during
power-up
Initially displayed during cold boot, will switch to
chassis address within 30 seconds
C
Critical
Steady >30
seconds from
power-up
If C remains longer than 30 seconds after power up,
the LBB has failed. Board may not be fully seated
or may have suffered a critical error during a
firmware upgrade.
F
Critical
Alternating with
chassis address
An error or event has occurred that requires human
intervention. Check disk LEDs and rear panel
LEDs. Also, check system status using NetCentral.
.
Informational
Blinking
throughout
operation
Indicates the LBB is functioning properly.
.
Critical
Blinking halted
The LBB has critically failed (steady for greater
than 30 seconds)
H
Informational
Alternating with
the chassis
address
A firmware update is in progress
H
Warning
Steady for short
duration with no
alternating
Ethernet link has been detected
H
Identify
Alternating with
the chassis
address
LBB has been sent an identify command by GVG
Disk Utility