beautypg.com

Lbb 7-segment display codes – Grass Valley PFR600/E User Manual

Page 43

background image

LBB 7-segment display codes

20 February 2004

PFR600/E Instruction Manual

43

LBB 7-segment display codes

The following table shows event codes for the rear panel 7-segment display on each
LBB.

Code

Type

Blink Rate

Meaning

0 thru 9

Informational

Steady or
alternating with
other code.

Chassis address. Refer to

“Chassis address setting

requirement” on page 28

.

A

Warning

Alternating with
chassis address

Fibre Channel speed has changed. Power cycle of
all connected RAID chassis is required.

C Power-up

Steady

during

power-up

Initially displayed during cold boot, will switch to
chassis address within 30 seconds

C

Critical

Steady >30
seconds from
power-up

If C remains longer than 30 seconds after power up,
the LBB has failed. Board may not be fully seated
or may have suffered a critical error during a
firmware upgrade.

F

Critical

Alternating with
chassis address

An error or event has occurred that requires human
intervention. Check disk LEDs and rear panel
LEDs. Also, check system status using NetCentral.

.

Informational

Blinking
throughout
operation

Indicates the LBB is functioning properly.

.

Critical

Blinking halted

The LBB has critically failed (steady for greater
than 30 seconds)

H

Informational

Alternating with
the chassis
address

A firmware update is in progress

H

Warning

Steady for short
duration with no
alternating

Ethernet link has been detected

H

Identify

Alternating with
the chassis
address

LBB has been sent an identify command by GVG
Disk Utility