beautypg.com

Grass Valley PDR 100 Master Enhanced Disk Recorder Board User Manual

Page 39

background image

Running System Board Diagnostics

PDR 100 Master Enhanced Disk Recorder

29

5. Select the

Master EDR

button in the board slot ID region on the Main

Diagnostics window. Test control buttons for the Master EDR board appear.

Another window, called DRSTART momentarily appears and is then
replaced by a GDB960 window and i960 diagnostics is loaded into EDR
memory. Test results will appear in this window which remains open until
you exit the Master EDR board menu.

6. When a

READY

prompt appears in the GDB960 window, select the

All

Tests

button on the Master EDR board menu.

7. Observe the messages which appear in the GDB960 window. If any

**FAILED**

message appears, the Master EDR board is bad and needs to be

replaced.

8. If no failures are noted, at the end of the tests, when

READY

re-appears,

select Done in the Master EDR board menu.

9. From the Diagnostics menu bar, select

Tests | All Board Tests

.

10. This executes diagnostics for all installed boards. The All Board Tests

diagnostic is dependent on the Master Enhanced Disk Recorder board
previously tested. Fully loaded systems take from 10 to 15 minutes to
complete the tests. Once initiated, you cannot cancel this diagnostics
operation.

11. Select

Quit

to exit the Main Diagnostics window.

If you have any board failures or any other unresolved installation problems,
contact your Grass Valley Group representative; see “Grass Valley Group
Product Support” at the front of this manual.

12. Once you have checked all the boards, shutdown and restart Windows NT.

To shutdown and restart the PDR100:

a. Press the CTRL+ALT+DEL key sequence.

b. Select

Shutdown and Restart

.

c. Select

OK

.

13.This concludes the procedure for running system board diagnostics.