Kayak HD — Installation and Service Manual

Section 2 — Installation

A hub can be used only if there is a need to exceed 328 ft. (100 m) between
a Control Panel and Video Processor frame. If a hub is used, connect the
hub to the switch via the Uplink port, or through a peer-to-peer crossover
cable.

Table 7

details Ethernet specifications. All Ethernet components are to be

supplied by the customer except the CAT5 crossover cable provided

Note

The supplied crossover cable works with the Kayak HD switcher because the
frame has an auto-sensing Ethernet switch.

CAUTION An existing facility Ethernet switch (not hub) can support Kayak HD if an ade-

quate number of ports are available. Keep your facility network and technical
network separate in order to avoid network traffic negatively affecting Kayak
HD system operation.

The Kayak HD backplane has four RJ45 Ethernet connectors for its built-in
Ethernet switch, each capable of 10/100/1000 Mbps. All Ethernet connec-
tors share the same speed- and direction-sensing features.

One Ethernet connector must connect to the Control Panel. It may go
through a switch to make the Control Panel connection, but at least one
connector must be connected from the Frame to the Control Panel
somehow.

One Ethernet connector may be connected to the Facility LAN if desired.
The other two Ethernet connectors may be connected to other devices if
needed.

Table 7. Ethernet Specifications

Cables

Type

10BaseT and 100BaseT compatible.
Category 5 cable, 8 conductor twisted pair.
The system will work at 10BaseT with reduced performance. 100BaseT
components are highly recommended.

Connectors

RJ-45 male connector at each end of cable.

Length

10BaseT: 984 ft. (300 m) maximum.
100BaseT: 328 ft. (100 m) maximum.
1000BaseT: 328 ft. (100 m) maximum.
Use hub or switch to exceed maximum cable runs.

Switch

Speed

10/100/1000 Mbps

Ports

RJ-45 auto-negotiating 10/100/1000 Mbps; number of ports required
is dependent upon system size. Frame ports are capable of 1000 Mbps.
Using a 1000 Mbps Ethernet switch enhances RAM Recorder transfer
speeds.

Unmanaged

Recommended. Configuration not required, but does not provide
remote monitoring capability.

Managed

May be used. Requires configuration, but offers remote monitoring
capability.