Grass Valley Kayak HD Installation v.6.9.4 Jun 02 2011 User Manual
Page 175

Kayak HD — Installation and Service Manual
175
Additional Kayak Panel FRUs
9.
Replace all screws, including the hex stand-off.
10.
Reconnect the fan housing connectors.
11.
Reconnect all cables, using the preceding instructions and/or refer to
the following table
12.
Transfer the existing CF Card from the old Panel CPU board to the new
one. For information about replacing the CF Card, see
Cards (2-M/E and 3-M/E) (128MB/512MB) on page 185
.
Table 12. Kayak Panel CPU Board—Connections Reference
From
To
RY4511/J21/50 Pin
RY4551/J1/50 Pin
RY4511/J17/50 Pin
RY4030/J1/50 Pin
RY4511/J15/50 Pin
RY4020/J1/50 Pin
RY4511/J14/50 Pin
RY4540/J1/50 Pin
RY4511/J6/40 Pin
RY3820/TFT Display
RY4511/J7/20 Pin
RY3820/J3/20 Pin
This manual is related to the following products: