Page 25
Front of CameraMan Camera
Appendix B: Troubleshooting
Problem:
The CameraMan autoTRACK Camera will not follow the Tracking
Ring Package.
Solution:
1. Is the POWER light on the CameraMans front panel illuminated?
If it is illuminated, proceed to step #2.
If it is not illuminated, make sure the Main Docking Station is
plugged in and its POWER switch located on the front panel is
moved to the ON position. The POWER light on the front of the
Main Docking Station should be illuminated.
2. Is the TRACKING UNIT STATUS light on the cameras front panel
illuminated?
If it is ON, proceed to step #3.
If it is OFF, make sure the Tracking Ring Power Pack is powered
ON.
If it is still OFF, check the Battery LOW light on the top of the
Tracking Ring Power Pack. If the Battery LOW light is illuminated,
then the battery is low and needs to be recharged.
If both the ON light and the LOW light on the top of the Power
Pack are not illuminated, then the battery may be completely
discharged and needs to be fully recharged.
If the battery is fully charged and the TRACKING UNIT STATUS
light is still OFF, check that the RF CHANNEL switch on the back
of the Main Docking Station matches the position of the RF
Channel switch on the back of the Tracking Ring Power Pack.
3. Is the autoTRACK light on the cameras display panel illuminated or
flashing?
If it is ON, proceed to step #4.
If it is OFF, use the Tracking System Keypad to select one of the
four autoTRACK View buttons.
4. If the POWER and the TRACKING UNIT STATUS lights are illuminated,
and the autoTRACK light is blinking,
Check to make sure that the Tracking Ring Sensors are attached
properly and are not covered by hair or clothing.
Be sure that you are standing in the field-of-view of the camera.
(904) 596-3500.
Step 1:
Is POWER light
ON?
Step 2:
Is TRACKING
UNIT STATUS
light ON?
Step 3:
Is autoTRACK light
FLASHING?
Power ON?
Battery
Charged?
RF Switch set to
the same
channel?