beautypg.com

Service – Grass Valley 8990ARC v.1.0 User Manual

Page 25

background image

8990ARC Instruction Manual

19

Service

Service

The 8990ARC Digital to Analog Converter modules make extensive use of
surface-mount technology and programmed parts to achieve compact size
and adherence to demanding technical specifications. Circuit modules
should not be serviced in the field unless otherwise directed by Customer
Service.

If your module is not operating correctly, proceed as follows:

Check frame and module power and signal present LEDs.

Verify power at the voltage tespoints (see

Figure 14

) and check Fuse F1

if no voltage is detected.

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).

Refer to

Figure 4

for the location of PWR LED and

Table 2 on page 6

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Figure 13. Refer to

Contacting Grass Valley Group

at the front of this

document for the Grass Valley Customer Service Information number.

Figure 14. Fuse and Voltage Testpoint Locations

8036_08

Fuse: 2 A FAST

125 V

F1

JP1

pin 3, +3 V

pin 5, -5 V

JP1

Voltage Testpoints

GND