beautypg.com

Service – Grass Valley 8981NR User Manual

Page 35

background image

8981NR Instruction Manual

35

Service

Service

The 8981NR modules make extensive use of surface-mount technology and
programmed parts to achieve compact size and adherence to demanding
technical specifications. Circuit modules should not be serviced in the field
unless directed otherwise by Customer Service.

If your module is not operating correctly, proceed as follows:

Check frame and module power and signal present LEDs.

Verify power at the voltage testpoints (see

Figure 15

) and check Fuse F1

if no voltage is detected.

Check for presence and quality of input signals.

Verify that source equipment is operating correctly.

Check cable connections.

Refer to

Figure 4

for the location of PWR LED and

Table 2 on page 12

for

proper LED indications.

If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.

Refer to the

Contacting Grass Valley

at the front of this document for the

Grass Valley Customer Service Information number.

Figure 15. 8981NR Fuse and Voltage Testpoint Locations

8226_08

Voltage Testpoints

JP6

+5V

-5V

3V

Fuse: 2 A Slow

125 V

F2A 125V

TEST

POINTS

F1