8981NR Instruction Manual

Power Up

Table 2. Board Edge LED Names and Meaning

LED

Indication

Condition

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault. (Refer to

Service

on page 35

.)

Flashing

Configuration problems. Check inputs and settings. Missing video.

COMM

(yellow)

Off

No activity on frame communication bus.

3 Quick Pulses

Locate Module command received by the module from a remote control system.

Short flash

Activity present on the frame communication bus.

CONF

(yellow)

Off

Module is in normal operating mode.

On continuously

Module is initializing, changing operating modes or updating firmware.

3 Quick Pulses

Locate Module command received by the module from a remote control system.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

525

(green)

Off

Input signal standard is other than 525.

On continuously

Valid 525 video signal is present

625

(green)

Off

Input signal standard is other than 625.

On continuously

Valid 625 video signal is present

2ND

(yellow)

Off

Rotary switch is addressing Bank 1 configuration functions

On continuously

Rotary switch is addressing Bank 2 configuration functions

DELAY

(green)

Off

Not Used

On continuously