Efer to – Grass Valley 8981NR User Manual
Page 12

12
8981NR Instruction Manual
Power Up
Table 2. Board Edge LED Names and Meaning
LED
Indication
Condition
FAULT
(red)
Off
Normal operation.
On continuously
Module has detected an internal fault. (Refer to
Flashing
Configuration problems. Check inputs and settings. Missing video.
COMM
(yellow)
Off
No activity on frame communication bus.
3 Quick Pulses
Locate Module command received by the module from a remote control system.
Short flash
Activity present on the frame communication bus.
CONF
(yellow)
Off
Module is in normal operating mode.
On continuously
Module is initializing, changing operating modes or updating firmware.
3 Quick Pulses
Locate Module command received by the module from a remote control system.
PWR
(green)
Off
No power to module or module’s DC/DC converter failed.
On continuously
Normal operation, module is powered.
525
(green)
Off
Input signal standard is other than 525.
On continuously
Valid 525 video signal is present
625
(green)
Off
Input signal standard is other than 625.
On continuously
Valid 625 video signal is present
2ND
(yellow)
Off
Rotary switch is addressing Bank 1 configuration functions
On continuously
Rotary switch is addressing Bank 2 configuration functions
DELAY
(green)
Off
Not Used
On continuously