beautypg.com

On the 8981nr module – Grass Valley 8981NR User Manual

Page 16

background image

16

8981NR Instruction Manual

Configuration

Table 3

provides a complete summary of the 8981NR processing functions

and a comparison of the functionality available with each control type
along with the ranges and default values for each parameter.

Table 3. Summary of 8981NR Configuration Functions

Control

Function

Type

Default

Range/Choices

Resolution

Web Page/

Function Name

Rotary Switch

Bank/Setting

Control

Panel

Mnemonic

Notes/

Conditions

Recursive filter

On

On/Off

Noise Filters/

Recursive Filter On/Off pulldown

2:3

RecrFilt

Recursive filter
enabled

Noise threshold

50.2%

0–100%

(0.4% steps)

Noise Filters/

Noise Threshold (%)

2:1

NoisThrh

Noise recursion coefficient

75%

0–100%

(0.8% steps)

Noise Filters/

Coefficient (%)

2:2

Coefient

Median filter

Off

On/Off

Noise Filters/

Median Filter On/Off pulldown

2:4

MediFilt

Display bar

Off

On/Off

Noise Filters/

Display Bar pulldown

1:1

DispBar

Split screen

Off

On/Off

Noise Filters/

Split Screen pulldown

1:2

SplitScr

Random noise generator

Off

On/Off

Noise Filters/

Random Noise Gen pulldown

1:3

RanNsGen

Impulse noise generator

Off

On/Off

Noise Filters/

Impulse Noise Gen pulldown

1:4

ImpNsGen

Random noise
gen must be on

Video proc amp

Off

On/Off

Proc Amp/

On/Off pulldown

2:5

ProcAmp

Video Proc
enabled

Y offset

0%

–3.5 to 3.4%

(0.11% steps)

Proc Amp/

Y Offset (%)

2:6

Y Offset

B-Y offset

0%

–3.5 to 3.4%

(0.11% steps)

Proc Amp/

B-Y Offset (%)

2:7

B-Y Ofst

R-Y offset

0%

–3.5 to 3.4%

(0.11% steps)

Proc Amp/

R-Y Offset (%)

2:8

R-Y Ofst

Y gain

100%

59.4 to 140.6%

(0.4% steps)

Proc Amp/

Y Gain (%)

2:9

Y Gain

B-Y gain

100%

59.4 to 140.6%

(0.4% steps)

Proc Amp/

B-Y Gain (%)

2:A

B-Y Gain

R-Y gain

100%

59.4 to 140.6%

(0.4% steps)

Proc Amp/

R-Y Gain (%)

2:B

R-Y Gain

Gain lock

On

On/Off

Proc Amp/

Gain Lock pulldown

2:C

N/A

Locks all gain
controls

Blank all vertical ancillary
lines

No

Yes/No

Vertical Ancillary Lines/

Blank All Lines pulldown

2:E (Blank or Pass)

BlankAll

Set blanking width in 525

Blank to

line 20

Blank to line 20
Blank to line 21

Blank Line 21 pulldown

2:D (Line 20 or 21)

Blank21

Blank all must
be yes

Save/Recall Registers 1–4

N/A

Registers 1–4

Recall or Save Settings/

Save Register #

Recall or Save Settings/

Recall Register #

1:A

(Save/Recall Reg 1)

1:B

(Save/Recall Reg 2)

1:C

(Save/Recall Reg 3)

1:D

(Save/Recall Reg 4)

N/A