Table 3. Summary of 8981NR Configuration Functions
Control
Function
Type
Default
Range/Choices
Resolution
Web Page/
Function Name
Rotary Switch
Bank/Setting
Control
Panel
Mnemonic
Notes/
Conditions
Recursive filter
On
On/Off
Noise Filters/
Recursive Filter On/Off pulldown
2:3
RecrFilt
Recursive filter
enabled
Noise threshold
50.2%
0–100%
(0.4% steps)
Noise Filters/
Noise Threshold (%)
2:1
NoisThrh
Noise recursion coefficient
75%
0–100%
(0.8% steps)
Noise Filters/
Coefficient (%)
2:2
Coefient
Median filter
Off
On/Off
Noise Filters/
Median Filter On/Off pulldown
2:4
MediFilt
–
Display bar
Off
On/Off
Noise Filters/
Display Bar pulldown
1:1
DispBar
–
Split screen
Off
On/Off
Noise Filters/
Split Screen pulldown
1:2
SplitScr
–
Random noise generator
Off
On/Off
Noise Filters/
Random Noise Gen pulldown
1:3
RanNsGen
–
Impulse noise generator
Off
On/Off
Noise Filters/
Impulse Noise Gen pulldown
1:4
ImpNsGen
Random noise
gen must be on
Video proc amp
Off
On/Off
Proc Amp/
On/Off pulldown
2:5
ProcAmp
Video Proc
enabled
Y offset
0%
–3.5 to 3.4%
(0.11% steps)
Proc Amp/
Y Offset (%)
2:6
Y Offset
B-Y offset
0%
–3.5 to 3.4%
(0.11% steps)
Proc Amp/
B-Y Offset (%)
2:7
B-Y Ofst
R-Y offset
0%
–3.5 to 3.4%
(0.11% steps)
Proc Amp/
R-Y Offset (%)
2:8
R-Y Ofst
Y gain
100%
59.4 to 140.6%
(0.4% steps)
Proc Amp/
Y Gain (%)
2:9
Y Gain
B-Y gain
100%
59.4 to 140.6%
(0.4% steps)
Proc Amp/
B-Y Gain (%)
2:A
B-Y Gain
R-Y gain
100%
59.4 to 140.6%
(0.4% steps)
Proc Amp/
R-Y Gain (%)
2:B
R-Y Gain
Gain lock
On
On/Off
Proc Amp/
Gain Lock pulldown
2:C
N/A
Locks all gain
controls
Blank all vertical ancillary
lines
No
Yes/No
Vertical Ancillary Lines/
Blank All Lines pulldown
2:E (Blank or Pass)
BlankAll
Set blanking width in 525
Blank to
line 20
Blank to line 20
Blank to line 21
Blank Line 21 pulldown
2:D (Line 20 or 21)
Blank21
Blank all must
be yes
Save/Recall Registers 1–4
N/A
Registers 1–4
Recall or Save Settings/
Save Register #
Recall or Save Settings/
Recall Register #
1:A
(Save/Recall Reg 1)
1:B
(Save/Recall Reg 2)
1:C
(Save/Recall Reg 3)
1:D
(Save/Recall Reg 4)
N/A
–