8910ADA-M/ST/SR — Instruction Manual

25

Module Configuration

Local or Remote Control

Set the module for Local or Remote control with jumper J4. When set to
LOC/POT (pins 1-2) the module settings are made locally with onboard
jumpers and switches and the hard-wired customer-supplied potentiome-
ters can be used. In LOC/POTmode, configuration from remote control is
locked out.

When LOC/REM

(local and remote) is enabled (pins 2-3), configuration

can be performed using the onboard switches, jumpers, and/or the web
browser or Newton Control Panel. When local settings are changed by the
remote control, the yellow

OVR

LED will illuminate if the remote settings

are different than the local ones.

Note

The hard-wired potentiometers only work in LOC/POT mode.

Output Mode Select

Use jumper P1 to select the output mode for Channel 1 and Channel 2 as
follows:

CHAN 1 Output

Input 1 – pins 1-2

Input 2 – pins 3-4

Sum 1 + 2 – pins 5-6

CHAN 2 Output

Input 1 – pins 7-8

Input 2 – pins 9-10

Sum 1 + 2 – pins 11-12

Phase Inversion

Use jumpers J2 and J3 to set Normal or Inverted input phase as follows for
each channel:

CHAN 1 Phase, Jumper J2

Invert – pins 1-2

Normal – pins 2-3

CHAN 2 Phase, Jumper J3

Invert – pins 1-2

Normal – pins 2-3