beautypg.com

Grass Valley 8910ADA-M User Manual

Page 20

background image

20

8910ADA-M/ST/SR — Instruction Manual

Power Up

Note

The yellow COMM and CONF LEDs are used for the module location function
that is enabled using the GUI. The module location function causes these
LEDs to flash concurrently three times followed by an off state of 900 ms
duration. The locate mode can be turned off by toggling the paddle switch on
the module.

Table 2

(-M and -ST modules) and

Table 3

(-SR module) show the possible

LED indications and conditions they indicate.

Table 2. 8910ADA-M/ST Indicator LEDs and Conditions Indicated

Version

LED

Indication

Condition

-M & ST

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault.

Long flash

Configuration problems. Check inputs and settings.

COMM

(yellow)

Off

No activity on frame communication bus.

Short flash

Activity present on the frame communication bus.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

Table 3. 8910ADA-SR Indicator LEDs and Conditions Indicated

Version

LED

Indication

Condition

-SR

FAULT

(red)

Off

Normal operation.

On continuously

Module has detected an internal fault.

Long flash

Configuration problems. Check inputs and settings.

COMM

(yellow)

Off

No activity on frame communication bus.

3 short on, 1 long off in

sync with CONF LED

Location Command received by the module from a remote control system.

Short flash

Activity present on the frame communication bus.

CONF

(yellow)

Off

Module is in normal operating mode.

3 short on, 1 long off in

sync with COMM LED

Location Command received by the module from a remote control system.

On continuously

Module is initializing, changing operating modes or updating firmware.

PWR

(green)

Off

No power to module or module’s DC/DC converter failed.

On continuously

Normal operation, module is powered.

PRESENT 1

(green)

Off

Input 1 signal is less than selected threshold setting (-20, -40 or -60 dBu).

On continuously

Input 1 signal is greater than selected threshold setting (-20, -40 or -60 dBu).

PRESENT 2

(green)

Off

Input 2 signal is less than selected threshold setting (-20, -40 or -60 dBu).

On continuously

Input 2 signal is greater than selected threshold setting (-20, -40 or -60 dBu).

OVR

(yellow)

Off

In Local/Remote mode, remote settings match local jumper settings on module.

On continuously

In Local/Remote mode, remote settings are overriding local jumper settings.

This manual is related to the following products: