8910ADA-M/ST/SR — Instruction Manual
Power Up
Note
The yellow COMM and CONF LEDs are used for the module location function
that is enabled using the GUI. The module location function causes these
LEDs to flash concurrently three times followed by an off state of 900 ms
duration. The locate mode can be turned off by toggling the paddle switch on
the module.
(-SR module) show the possible
LED indications and conditions they indicate.
Table 2. 8910ADA-M/ST Indicator LEDs and Conditions Indicated
Version
LED
Indication
Condition
-M & ST
FAULT
(red)
Off
Normal operation.
On continuously
Module has detected an internal fault.
Long flash
Configuration problems. Check inputs and settings.
COMM
(yellow)
Off
No activity on frame communication bus.
Short flash
Activity present on the frame communication bus.
PWR
(green)
Off
No power to module or module’s DC/DC converter failed.
On continuously
Normal operation, module is powered.
Table 3. 8910ADA-SR Indicator LEDs and Conditions Indicated
Version
LED
Indication
Condition
-SR
FAULT
(red)
Off
Normal operation.
On continuously
Module has detected an internal fault.
Long flash
Configuration problems. Check inputs and settings.
COMM
(yellow)
Off
No activity on frame communication bus.
3 short on, 1 long off in
sync with CONF LED
Location Command received by the module from a remote control system.
Short flash
Activity present on the frame communication bus.
CONF
(yellow)
Off
Module is in normal operating mode.
3 short on, 1 long off in
sync with COMM LED
Location Command received by the module from a remote control system.
On continuously
Module is initializing, changing operating modes or updating firmware.
PWR
(green)
Off
No power to module or module’s DC/DC converter failed.
On continuously
Normal operation, module is powered.
PRESENT 1
(green)
Off
Input 1 signal is less than selected threshold setting (-20, -40 or -60 dBu).
On continuously
Input 1 signal is greater than selected threshold setting (-20, -40 or -60 dBu).
PRESENT 2
(green)
Off
Input 2 signal is less than selected threshold setting (-20, -40 or -60 dBu).
On continuously
Input 2 signal is greater than selected threshold setting (-20, -40 or -60 dBu).
OVR
(yellow)
Off
In Local/Remote mode, remote settings match local jumper settings on module.
On continuously
In Local/Remote mode, remote settings are overriding local jumper settings.