Ensemble Designs 5400 Dual Sync Generator and Test Signal Generator with HD Tri-Level Sync User Manual
Page 28

The HD Sync menu screen shown below allows you to set the HD standard and timing of
the HD Sync output in relation to the Primary serial output with the following controls.
For numerical choices, use the slider control to select a value or touch the number field at
right to bring up a pop-up keypad. Enter a value and press the Enter key.
•
HD Standard – select the desired high definition standard for the sync output.
•
Ver Timing – set the vertical timing in relation to the Primary serial output in
clocks.
•
Hor Timing – set the horizontal timing of the HD sync output in relation to the
Primary serial output.
The Config menu allows you to configure the reference from the external input (525, 625
or 10 MHz sine wave) or the Master Frame Reference:
•
Config Ref – select the desired module reference from the external input (525, 625
or 10 MHz sine wave) or Master Ref (Frame Reference).
The presence of the reference will be reported in the adjacent window.
•
Pulse Select – set the type of pulse output desired for the AES Out 2/Wordclock
BNC on the rear of the frame. (Note that to enable a Wordclock or 6 Hz Pulse
output, jumper J3 must be set to WDCLK on the 5410 submodule. Refer to the
Installation section of this data pack for an illustration of this jumper.)
•
Make EDH Error – this function allows introduction of specific EDH errors into
the SDI output stream for.testing downstream equipment. when the 5410 option is
present It can also be used to verify that corrective action or alarms are generated
at those downstream points as needed or expected. This mode resets to No Errors
upon reset or power is cycled (setting is not stored in non-volatile memory.) Error
types are summarized as follows:
•
AP CRC Error – causes incorrect CRC for active picture to be transmitted
in EDH packet. Simulating a bit error, this should be detected as an EDH
error by downstream equipment.
5400-28
Model 5400 Dual Sync Gen/Test Signal Generator